Laserfiche WebLink
9. The riser height for L'xit 3 exeeeds allowuble dimensions per IBC ]0093. Thc clear width should be <br /> dimensioned so that handrails do not cxcecd the maximum projections into dic cicar width per IBC <br /> 1009.I 1.7. <br /> ]0. The drawings fbr tlic support oC the glass are not suf(icicntly detailed to specify insialistion of giazing <br /> with an unsupportcd cdgc, per 1I3C 2403.2 and 24033. Thc glazing matcrials should be indicatcd on thc <br /> drawings to meet the rcyuiremcnts of IBC 2405.2. Scmens are rcquired for the height of the glazing <br /> indicntcd on Section 5/A5.01, per IBC 24053. All storeGont glazing panels parallel and adjacent to <br /> doors (with Aic lowest edge Iess than GO inches from the walking surface) are required to Ue tempercd, <br /> per IBC 240G3 (G). <br /> 11. llissimilar metals indicated in the building canopy extcnding through 'he masonry wall (Sections 5 & <br /> 13/A5.01) should Ue isolated to minimize galvanic corrosion, per IBC 2�011 J. ,� <br /> 2�03 • '� � <br /> 12. Special [nspectians are requircd for EIPS cladding, per IBC 1704.12. <br /> 13. The insulatimi indicated on Q�e roof and at the slaU on grade for lletail 17/A5.02 should be ideutified on <br /> the drawings and dcmonstrated in supporting material to mect one of thc nptions for the building <br /> envelope compliancc identified in WS�C I�igure 13A. <br /> 14. The vault or sprinkler room should Uc indicated on the shell building dra��ings to mcet thc rcyuirements <br /> of the City of T:verett PuUlic Works Double Chcck Detecior Vah-e AssemUly Drawings ;I5, 516 or >23 <br /> (sec attachcd). <br /> Applicablc codes includc the 2003 Intcrnational Building Codc (IBC), tl�e 2003 Intcrnational Ivicchanical Code <br /> (IN.C), the Washington State Gnergy Code (WSGC), 2004 edition, the Washington Statc Ventilation and Indoor <br /> Air Quality Codc (VIAQ), 2003 L'dition, and the AccessiUle and Usable Buildings and I�acilities ICC/ANSI <br /> �117.1-2003 (ICGANSIL All codes refcrenced, as adopte�l by tlic City of Everett, should include current <br /> rcvisious by the State of Washington. These commene, address building issues anly. Revisions or additiuns <br /> may be required by other depariments(such as iJtilities,Planning or Pirc). <br /> Upon submission of thc revised drawings, yaur applic,�tion will Ue given prionty and plan review will begin. <br /> All required submittals must be of suf�icicn[ detail and information to ensure lha[ thc proposed sWeture will be <br /> constructcd in compliance with all adopicd codes. Ple.se call mc to discuss any of these comments at 425-257- <br /> 8813. <br /> Sym;ercly, <br /> . � �i �—� <br /> M g M. Haley <br /> Plans Cxmninc <br /> � <br /> .—�� <br /> S:Ab1PlalcyV15'orJA60610-003 I 130 SG P.vcrett�1:�11 AVay LcUcr.Joc ��� <br />