Laserfiche WebLink
DIBBLE ENGINEERS, INC. <br />Professional Structural Engineering San,' <br />Boh Ramsey <br />Charter Construction <br />980 South Harvey Street <br />Seattle, WA 98108 <br />August 30", 2011 <br />DEI Project: 11-176 <br />Scope of <br />Re-bair <br />Plan Check No.: <br />Job Address: <br />B1109-014 <br />1205 SE EVERETT MALL WAY <br />Owner: <br />EVERETT MALL 01 LLC <br />Tenant: <br />[TenName] <br />Application Date: <br />9/8/2011 <br />Proposed Use: <br />Type of work% <br />FIRE DAMAGE REPAIR - LV NAI <br />Office Sek 1 — <br />Job Set Fire/Planning Se <br />q <br />Reviewed For Permit: Date: 1 "�l By <br />Re: Everett Mnll Fire Damage, Scope of Repair <br />Dear Mr. Ramsey: <br />damge <br />The purpose of this report is to summarize and or.tliue the scope Everett,of reparWA. Dibble Engineers of the Inc. <br />sustained to the business located at 1205A-D Everett Mall Way,age caused by <br />e dam <br />(DEI) performed two consecutive site visits on August 22h animand s lereview forstructural damage wash <br />accidental fire. Minor damage was due to the fire itself - <br />Thep �3 their haste, chainsaws were <br />due to the fire departments attempts to ventilate and secure the building• <br />In used to open up sections of the roof to allow smokedtoo exit. Theseifferent spen�ed were <br />made with no attention <br />to the existing truss structure and as a result, many <br />Based on the damages observed, repairs should be made as follows: <br />In locations where the top chord of the truss has been notched/sliced/cut: <br />1. Fill the cut with either SET22 or SETXP epoxy <br />2. Sister anew 6' long 2'x4' to each side of the top chord using IW' x 3" SDS screws. (SK-2) <br />3. Screws should be attached at 6" o/c with 4" end between the cut and first screw <br />Hi locations where the top chord is missing lengths of 1" or more or where adjacent cuts reside within 12ft <br />of each other or where there are more than two cuts on any single truss: <br />1. Replace the entire truss with like ldnd to match original <br />2. Reattach to bearing walls to match original <br />In locations which appear to have sustained fire damage: <br />1. Contractor shall survey all damaged framing and sheathing <br />2. Remove all fire damaged Gypsum, sheathing, framing and debris in the vicinity of the <br />3. Remove all insulation that is water saturated or damaged <br />Pagel oft P.425-818-4200 <br />1029 Market Street F. 425-827-6131 <br />Kirkla)ad, WA98033 <br />