Laserfiche WebLink
Page 2 I ' <br />�fichanl Lackey, Archttect � <br />I. E. The building does not comply with unllcnited areaa per <br />Section 506 (b) and In accordance with (�eneral notad sUove. <br />I. (AddFtlor.al Comment) Che�k Sec. 504 (c) fo.r the possLMlity <br />tnat courte'exist, or that tl:e malle a••ay be �:onetdered as <br />courie. 'The mall area may be includect ae floor area <br />(Sec. 407, Floor A �ea). <br />III-C R.efer to Table 17A for minimum etructurel ftre raeietance <br />requtromenta in exterlor walle. <br />IV-A �Ve do not entlrely agree that the mall ie to be coneidered <br />as a public way. If it ie considered a public way, property <br />lines become eataUlished. See Sec. 504 (a�, second para- <br />graph. We will baee the interpretatfon to your beat advantage. <br />However, until the plana can b� reviewed, we reeerve the right <br />to question thie point. <br />IV-C The meaning of the word "net" Eor figuring occupant load is not <br />clear. Our interpretatlon ie that all of the area within the wall <br />1{nea ie to be uaed to figure occupanE load. Fixture area is <br />includad in figuring occupant load. Fixtures can be removed <br />at some future time eo tha building must be able to provide the <br />requiremente for the maximum poselble load. <br />IV-T (New paragraph) Section 3304 muat be considered if corridors <br />are Included t.n the building. <br />IV-R Exceptlon: The exception ie not approved by our r ire vIarshal. <br />Illuminated axit eigna ehall be lnetalied at front entrancee. <br />IV-S 2a: The Fire Vtarahal hae additional illuminated extt eign <br />requiremente. Illuminated exit eigne are required if the occupant <br />load ie 100. <br />VI-TJ (Add[tional paragraph): A 25# per square foot roof load ie <br />required. �Ye are in the 25� par square foot wlnd preaeure area. <br />Very truly youre, <br />John H. Farrene <br />Plane Examiner <br />JHF:es <br />