My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 SE EVERETT MALL WAY GAMESTOP 2018-01-02 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1402
>
GAMESTOP
>
1402 SE EVERETT MALL WAY GAMESTOP 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2022 5:45:46 PM
Creation date
2/13/2017 7:54:49 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1402
Tenant Name
GAMESTOP
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0nna WA , .ninn State Nonresidential Enerov Code Compt' -ce Form <br />2006 Washington State Nonresbenlial Energy Gods Comphamm Forms Revised JNy 2007 <br />Project Address 1402 S.E. EVERETTE 1esr.L WAY SPACE R190 <br />Date 5/3/2011 <br />The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the <br />Washington State Nonresidential Energy Code. <br />Applicability <br />(yes, no, n.a.) <br />Code <br />Section <br />Component <br />Information Required <br />Location <br />on Plans <br />Building Depadment <br />Notes <br />HVAC REQUIREMENTS (Sections 1401-1424) <br />1411 <br />Equipment performance <br />yes <br />1411.4 <br />Pkg. elec. htg.& clg. <br />List heat pumps on schedule <br />M3 <br />yes <br />1411.1 <br />Minimum efficiency <br />Equipment schedule with type, capacity, efficiency <br />M1 <br />. a . <br />1411.1 <br />Combustion htg. lindicate <br />intermittent ignition, flue/draft damper & jacket loss <br />1412 <br />HVAC controls <br />yes <br />1412.1 <br />Temperature zones <br />Indicate locations on plans <br />M7 <br />yes <br />1412.2 <br />Deadband control <br />Indicate 5 degree deadband minimum <br />M2 <br />no <br />1412.3 <br />lHumidity control <br />Indicate humidistat <br />yes <br />1412.4 <br />lAutomatic setback <br />Indicate thermostat with night setback and 7 diff. day types <br />M2 <br />yes <br />1412.4.1 <br />Dampers <br />Indicate damper location and auto. controls & max. leakage <br />H1 <br />. a. <br />1412.4.2 <br />Optimum Start <br />Indicate optimum start controls <br />yes <br />1412.5 <br />1 Heat pump control <br />Indicate microprocessor on thermostat schedule <br />M1,M2 <br />. a. <br />1412.E <br />lCombustion htg. <br />Indicate modulating or staged control <br />Yes <br />1412.7 <br />18alancing <br />Indicate balancing features on plans <br />M1 <br />1412.8 <br />lVentilation Control <br />Indicate demand control ventilation for high -occupancy areas <br />. a. <br />1422 <br />IThermostat interlock <br />Indicate thermostat interlock on plans <br />yes <br />1423 <br />lEconomizers <br />Equipment schedule <br />M1,M2 <br />1413 <br />JAIr economizers <br />yes <br />1413.1 <br />lAir Econo Operation <br />11ndicate 100% capability on schedule <br />M1 <br />. a. <br />1413.1 <br />Mir Econo Operation <br />lindicate 100% capacity at 45 degF db & 40 deg F wb <br />. a. <br />14132 <br />Water Econo Doe <br />Indicate clg load & water sconce & clg tower performance <br />. a. <br />1413.3 <br />Integrated operation <br />Indicate capability for partial cooling <br />. a. <br />1413.4 <br />Humidification Indicate direct evap or fog atomization w/ air economizer <br />1414 <br />1 Ducting systems <br />. a. <br />1414.1 <br />Duct sealing <br />Itndicate sealing necessary <br />yes <br />1414.2 <br />Duct insulation <br />I Indicate R-value of insulation on duct <br />H1 <br />yes <br />1415.1 <br />Piping insulation <br />Indicate ?-value of insulation on piping <br />M1 <br />141E <br />lCompletion Requirements <br />yes <br />1416.2.1 <br />lCommissioning <br />Provide commissioning plan <br />yes <br />1416.2.2.3 <br />Sys.Bal & Func.Test <br />Indicate air and water system balancing & functional testing <br />yes <br />1416.2.4 <br />Commissioning <br />Indicate O&M manuals, record drawings, staff training <br />yes <br />1416.2.5 <br />Comm. Report <br />Indicate requirements for prelim. & final commissioning report <br />. a. <br />1434 <br />Separate air sys. <br />Indicate separate systems on plans <br />yes <br />Mechanical <br />Summary Form <br />Completed and attached. Equipment schedule with types, <br />input/output, efficiency, cm, hp, economizer <br />(Sections <br />1440 <br />1 Service water htg. <br />. a. <br />1441 <br />Elec, water heater <br />Indicate R-10 insulation under tank <br />.a. <br />1442 <br />Shut-off controls <br />Indicate automatic shut-off <br />yes <br />1443 <br />Pipe Insulation <br />Indicate R-value of insulation on piping <br />P7 <br />. a. <br />1452 <br />Heat Pump COP <br />Indicate minimum COP of 4.0 <br />. a. <br />1452 <br />Heater Efficiency <br />Indicate pool heater efficiency <br />. a. <br />1453 <br />Pool heater controls <br />Indicate switch and 65 degree control <br />.a. <br />1454 <br />Pool covers <br />lindicate vapor retardant cover <br />. a. <br />1454 <br />1 Pools 90+ degrees <br />11ndicate R-12 pool cover <br />If "no" is circiea for any question, provrae exprunalrvn: <br />
The URL can be used to link to this page
Your browser does not support the video tag.