Laserfiche WebLink
August 12, 2015 <br />� <br />'UBL/C K/ORKS <br />Larry E3omfe <br />la�a�[mbricka ndblock.com <br />RE: Owner. Scott 721 [nterprise LLC <br />Job Address: 221 SE Everelt �1all bVay <br />Plan Chec� h'o: 3:SOfl-012 <br />Dear t�is. Bonife, <br />� <br />In response lo your applicaUon for a cons;ruction peimit, your plans have been exaiT�ined and yeu are <br />advised that revisions may be necessary before a permlt can be issued. Please review and respond to the <br />commen[s below. These comments address building issues only. Additional revisions or additions n��ay be <br />required by o[her departments (such as Utilities, Planning or Fire). All re(erences refer to the 2012 <br />lntemational Bwlding Code (IBC), the 2012 Intemational Fire Code (IFC), the 2012 In[ernational <br />��techanical Code (IhiC), and the 2012 Intemational Energy Conservation (IECC), as amended by the <br />State of Washington and adopced by the city of Everett. The current IBC referenced standard For <br />accessible design is the 2009 "�cc•_ssible and Usabte Buildings and Facllities" (ICC/ANSI A117.]). Federal <br />ADA regulations and standards may be more resUictive. <br />In order for the processing of your application to continue, it will be necessary to provide the <br />Building Division with two complete new sets of construction documents reflecting the <br />corrections requested. <br />The proposed table and cnair plan indicates an occupant based on 42 chairs. Since this <br />number is less than �vhat would result from applying IBC section 1009.1.2, il is assumed you <br />may be anti�ipating the use of the exception to that section. The bwlding official would <br />approve the use of the exception sobject to the (ollowing; <br />• The estabGshment be posled with a sign complying with IBC 100�i.3 for a total <br />establishment maximum occupancy of 50. <br />• The front door be equipped with panic h.irdware per I6C 1009.1.10. <br />• The front door be posled �vilh ar. exit sign complying �vdh If3C lOt 1. <br />If you have any questions, please call me at 425-257• 7264. <br />Please prepare a response letter showmg wherc each item in this corrections Ietter is addressed on Uie <br />plan set. <br />Upon submittal of lhe drawings, your application will be given prionty and plan reviews witl recommence. <br />All required submittals shall be sufficient detail and contain sufficient informalion to ensure lhat the <br />proposed structure will be conslructed in compliance with all adopted codes. <br />�� . <br />Sincerely, �,� <br />Steve Miller <br />Associate Engineer <br />CITY OF EVERETT • 3200 Cedar Street • Evereh, .VA 98201 •(425) 257-8800 • Fax (425) 257-8882 <br />