Laserfiche WebLink
2006 W inaton State Nonresidential Energy Code <br />July 2007 <br />Project Address 31 SE E.vurett D1a11 Nay, Lot 2 <br />Date 9/6/2007 <br />Space Heat Type <br />Q Electric resistance Q All other <br />For Building Department Use <br />Glazing Area as % gross exterior wall area <br />21. 9% Prop. <br />45, 0% Max Target <br />Concrete/Masonry Option <br />OYes QQ No <br />Notes: If glazing area exceeds maximum allowed in Table. then calculate adjusted areas on back (over). <br />Building Component <br />Proposed UA <br />Target UA <br />List components by assembly IDS page p <br />U-factor x Area A = UA U x A <br />U-factor x Area A = UA U x A <br />U= 0. 550 Plan ID A0.0, A2.0 <br />0.550 1426.7 784.7 <br />0.550 1426.7 784.7 <br />Glazing °% Electric Resist. Other Heating <br />U= Plan ID: <br />U= Plan ID: <br />0-30% 0.40 0.55 <br />rn <br />U= Plan ID: <br />>30-45% see note above 0.45 <br />> a <br />U= Plan ID: <br />U= Plan ID. <br />U= Plan ID: <br />U= Plan ID: <br />0.700 <br />Glazing °% Electric Resist. Other Heating <br />¢ <br />U= Plan ID: <br />m <br />w <br />U= Plan ID: <br />0-30% 0.6 0.7 <br />_NM <br />O <br />O <br />U= Plan 10: <br />>3045% see note above 0.6 <br />a <br />v <br />U= Plan to <br />t <br />00 <br />U= Plan ID: <br />O <br />c <br />U= Plan ID: <br />0.700 <br />O <br />U= Plan ID: <br />0 <br />U= 0. 600 Plan ID Ao.O <br />0. 600 126.0 75.6 <br />0.600 126.0 75.6 <br />Electric Resist. Other Heating <br />n12 <br />U= Plan ID: <br />O <br />U= Plan ID. <br />0.60 0.60 <br />Plan ID. <br />0.036 <br />Electric Resist. Other Healing <br />3 > <br />IR= <br />R= Plan ID: <br />c 0 ° <br />R= Plan ID. <br />0.031 0 036 <br />R=21.0 Plan to A4.1 -4.4 <br />0.046 7627.0 350.8 <br />0.046 7627.0 350.6 <br />Electric Resist. Other Heating <br />`m <br />g <br />R= Plan ID: <br />1R= <br />0 oc <br />Plan ID: <br />0.034 0.046 <br />R=19.0 Plan to A4.1 -4.4 0.109 4964.0 541.1 <br />R= Plan 10: <br />0.109 4964.0 541.1 <br />R= Plan to: <br />Electric Resist. Other Heating <br />m <br />3 <br />R= Plan ID: <br />R= Plan ID: <br />Frame-Wd 0.062 0.062 <br />$ <br />R= Plan ID: <br />Frame-A1ll 0.062 0.109 <br />0 <br />R= Plan 10. <br />Mass Wall" 0.15 0.15 <br />"Note: sum of Target Areas here should equal Target Opaque Wall Area (see back) <br />++ see mass wall Criteria <br />R= Plan ID. <br />Electric Resist. Other Healing <br />0 ° <br />R= Plan ID: <br />a L 2 <br />R= Plan ID: <br />Int Ins 0.062 0.062 <br />Note: if insulated to levels required for opaque walls, list above with opaque walls <br />Ext Ins 0.07 0.07 <br />c <br />Plan ID: <br />0.056 <br />Electric Revd Other Heating <br />3 m <br />R= Plan ID: <br />` C <br />IR= <br />R= Plan 10: <br />0.029 0.056 <br />R= Plan ID: <br />s y <br />R=10.0 Plan ID A4.1 -4.4 <br />0.540 7627.0 4118.E <br />0.560 7627.0 4118.6 <br />Electric Resist. Other Heating <br />c <br />R= Plan ID: <br />6 aa <br />R= Plan ID: <br />F=0.54 F=0.54 <br />R= Plan ID: <br />I <br />(see Table 13-1 for radiant floor values) <br />'For CMU walls, indicate core insulation material. Totals <br />21770.7 <br />5870.E <br />Totals <br />0.7 <br />51370. 8 <br />To comply: 1) Proposed Total UA shall not exceed Target Total UA. <br />2) Proposed Total Area shall equal Target Total Area. <br />3l� <br />