My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
406 SE EVERETT MALL WAY BASE FILE 2018-01-02 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
406
>
BASE FILE
>
406 SE EVERETT MALL WAY BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2022 3:45:08 PM
Creation date
2/13/2017 8:23:41 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
406
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TILT -UP WALL DESIGN <br />------------------- <br />fc = 3,000 psi. <br />fy = 60,000 psi. <br />Actual Thickness = 5.500 in. <br />Design Thickness = 4.750 in. <br />Height = 16 ft. (Distance between ledger and floor) <br />Height of parapet = 2.50 ft.. .` <br />Tributary width 3.33 ft.�% <br />Roof dead load = 6000 pounds per width b ( 40 in.) <br />Roof live load = 12540 pounds per width b ( 40 in.) <br />Wind load 19 psf. is <br />Seismic Zone 3 <br />Eccentricity = 6.5 in. <br />Depth to steel = 3.69 in. <br />CASE IA U=-1_4(D)-+-1_7(L) M_P*e-@- roof -(No P* deflection) <br />Moment under factored loads Mu= 16,097.25 ft-lbs/width b <br />Phi times nominal moment (PhiMn) = 22,152.32 ft-lbs/width b <br />As.-1.234 sq in/width b ) <br />7 -# 4 As- 1.37 sq.in.---Cacfirol5 <br />4 -# 5 As= 1.23 sq.in. ;,; q.` < ;{.'=9"rti�eiAIN <br />• CASE IBU_ -- - 1.4(D)+1_- 7(L)M__6*P*e + P*deflection <br />- -- <br />Moment under factored loads Mu= 18,338.41 ft-lbs/width b t <br />Phi times nominal moment (PhiMn) = 18,426.55 ft-lbs/width b <br />Deflection under service loads = .636 in. < Allowable Deflection = <br />Moment under service loads Ms= 7,125.58 ft-lbs/width b <br />As.- .888 sq in/width b <br />5 -# 4 As= .98 sq.in. <br />3 -# 5 As= .92 sq.in. <br />CASE II U = .75(1.4D+1.7L+1.87E) 50 8 Live load <br />Moment under factored loads Mu= 10,695.76 ft-lbs/width b <br />Phi times nominal moment (PhiMn) = 10,886.67 ft-lbs/width b <br />Deflection under service loads = .793 in. < Allowable Deflection = <br />Moment under service loads Ms- 6,594.71 ft-lbs/width b <br />AS.- .466 sq in/width b <br />3 -# 4 As= .59 sq.in. <br />2 -# 5 As= .61 sq.in. <br />1.92 in <br />1.92 in <br />CASE III U = .75(1.4D+1.7L+1.70W) 50% Snow load <br />----------------------------------------------- <br />Moment under factored loads Mu= 10,984.46 ft-lbs/width b <br />Phi times nominal moment (PhiMn) = 11,143.24 ft-lbs/width b <br />Deflection under service loads .879 in. < Allowable Deflection = 1.92 in <br />oment under service loads Ms- 7,074.75 ft-lbs/width b <br />_ .484 sq in/width b <br />-# 4 As= .59 sq.in. <br />2 -# 5 As= .61 sq.in. <br />CASE Iv U = .9(D)+1.43(E) <br />-------------------------- <br />Mnmpni- undo r far MrPrl 'loads Mu= 5,631.84 ft-lbs/width b <br />
The URL can be used to link to this page
Your browser does not support the video tag.