My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
500 SE EVERETT MALL WAY KELLER WILLIAMS REALTY 2016-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
500
>
KELLER WILLIAMS REALTY
>
500 SE EVERETT MALL WAY KELLER WILLIAMS REALTY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2017 1:03:47 PM
Creation date
2/13/2017 8:26:26 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
500
Tenant Name
KELLER WILLIAMS REALTY
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Deccmbcr 1, 200G <br />'NGINEERING / PUE�LIC SERVICES DEPARTMENT <br />Mr. Adam Clark <br />Gary Parkinson Architects <br />2812 Colby Avenue <br />�verett, WA 98201 <br />Project: Keller Williams Realty <br />Job Address: 500 SE Everett Mall Way <br />Plan Revie�v No: B0611-002 <br />Dear Mr. Clark, <br />In response to your application for building construction permit, lhe plans have been examined and you are <br />advised that a permit cannot be issued until the following issucs are resoived. <br />1. Since the egress of the first floor is being revised in this tenant improvement, it may affect the required <br />egress of other tenants on the floor. A complete first floor plan is required to cvaluate the proposed <br />separation of tl�e front ei�trance from other tenants' usage. A current first floor plan should be provided, <br />minimally indicating egress, occupant loads, and occupancy types. <br />2. T'he con�Wction type of the building was revised on this application to II-B; on the shell permit the <br />construction type was identified as Type III-B. Additional verification is required from all tenants and <br />the „wner of tUe building to change the conslruction type to a more restrictive type. <br />3. �ach iloor of the tenant improvement should indicate existing and new emergency lighting and signage, <br />to include: <br />• Illuminated exit signage at exits and exit access doors, per IBC 101 l.l. <br />• Emergency egress lighting, per IBC Section 1006.3. <br />• Tactile exit signs, per IDC Section 1011.3. <br />Note that the Team nffice Room 137 requires egress lighting and signage outside of an inside of tl�e <br />room, since it is an intervening room included in the exit access, per IBC Section 1013.2. <br />4. All locations of safety glass should be noted on the plans in hazardous locations for new construction, <br />per IDC Section 24063 <br />5. The counter height in the toilet rooms and in the Break Room 112 should not exceed 34 inches, per <br />AN3I Sections 60G3 and 902.3 <br />These comments address building issues only. Revisions or additions may be required by other departments <br />(such as Utilities, Planning or Pirc;. Applicable codes include We City of Everett adopted 2003 editions of the: <br />Intemational Building Code (IBC), Uttemational Mechanical Code (IMC), Washington State Ventilation and <br />Indoor Air Quality Code (VIAQ), Accessible and Usable Buildings and Facilities A117.1-2003 (ICC/ANSn, <br />and the 2004 ediNon of the Washington State Lnergy Code (WSEC), including revisions by the Slate of <br />Washington. These comments address building issues only. Revisions or additions may be required by other <br />depariments (such as Utilities, Planning or Pire). <br />CITY OF EVEAETT • 3207 Cedar Street • Everett, WA 98201 •(425) 257-5800 • Fax (425) 257-8856 �/.L <br />s:uui,i�y�wo�mnau-ooz soose c.�e�n m,n w,y.e« <br />
The URL can be used to link to this page
Your browser does not support the video tag.