Laserfiche WebLink
Ti�ornas M. Haiha <br />� <br />2772 Chapman Road <br />Scappoose Oregon 97056 <br />503 543-8387 <br />OctoUer 4, 2004 <br />Tony Lee <br />Plans Examincr <br />City oFEverett <br />Proj�xt Galaxy Casino <br />607 SE �verelt Mall Way # I <br />Plen Revicw No. B0409-026 <br />Response to Cammenls <br />1. Genc Benrcu nt tho office of Industrial Prelratmcnt has bccn contacted, cnd his requirements for <br />gease removal will be met. <br />2. The project cfata secrion of the cover shect now calls out the occupancy classification (A-3), type of <br />conshuction (VN, non-sprinklered), and applicable codc (2003 IBC). <br />3. New blow-in insulation will be added to thc existing un-insulated exterior walls on il�e wcst side of <br />the building. A notc has been addcd to the floor �!an for this requircmeni <br />4. The door swing direction at the mnin entry doocs has bcen mvised to mntct� tha direction of egess. <br />5.'Ihe exit si�s have now been sho�m on the reflccted ceiling pinn. <br />6. A nofe has becn added to the plm� calling out e�tist signs lhnt are in�emally illuminated wi�h 90 <br />minute battery back-up power. <br />7. A note hns been added to Ihe pinn calling out tactile exic signage per seclion 10113 <br />8.'I7�e occupant loads for the nssembly rooms have been called out on ilie plan. <br />9. A note has been added to the plan calling out exit illuminntion with emergency power at access arca <br />to requimd exit doors in ihe assembly a�eas and at the exterior exit discharge areas. <br />10. 5 water closets havc now been shown in tho Women's room. <br />11. The hallways accessing thc roilet rooms have been widened to provide 48" clear width. <br />Sincerely, <br />T!� �•��► <br />Tom Houha. Architect <br />T'd Z806-LZ6 ESZ eynoH wol dtE��T b0 b0 z�0 <br />