My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
620 SE EVERETT MALL WAY AUTHENTIC ASIAN AMERICAN BUFFET 2016-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
620
>
AUTHENTIC ASIAN AMERICAN BUFFET
>
620 SE EVERETT MALL WAY AUTHENTIC ASIAN AMERICAN BUFFET 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2017 3:49:19 PM
Creation date
2/13/2017 8:40:47 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
620
Tenant Name
AUTHENTIC ASIAN AMERICAN BUFFET
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M�y to, 2oio <br />Mr. David Lec <br />( <br />Puecic wa�as <br />Techcraft Carp. <br />2126 NW 204°i Street <br />Shoreline, Washington 98177 <br />Project: 'Cype I Flood 1br AAA I3uffet <br />Job Address: 3025 Lombard Ave <br />P!an Revicw No: M 1004-037 <br />Sent via e-mail <br />s/,o li� <br />Dear Mr. Lce, <br />In response to your application for a mechanical and Type I hood pennit, tl�e plans have been examined and you <br />are advised that a permit cannot be issucd until the following issues are resolvcd, and hvo set of slip-sheeted <br />documen4s are submittcd for revicw. Por clarification, please cloud and identify any revisions to the drawings <br />from what was originally submitted for permit. <br />Typc I Iiood Revicw: <br />�I. Pcrmanent roof maintenance access (fixed laddcr or slair) is required when thc Type I hood exhaust fan <br />termination is installed on roofs at a hcight escecding 1 G feet, per IMC section 30G.5. <br />„2. A roof platfonn to scrvicc lhe Typc 1 hood exhaust fan and duct is required when tlie roof slope is 25% <br />or greatcr (3:12), per IMC section 30G.5.1. <br />' 3. Latcral support or calculations and details from a licensed professional engineer are required for thc <br />wall enclosure of thc Type I hood c�l�aust fan abave the roof. <br />�/ 4. <br />�5 <br />[f the wall perpendicular to the Type 1 Hood contains wood studs, then mineral wool alonc is not <br />sufficient to reduce the clearancc requiremcnts from 18 inches to 6 inches, per IMC Table 308.G. The <br />drawings should specify the exact assembly as described per IMC Table 308.G. <br />The intcrior �vall treatment of tlie side wnll adjacent to the Type I hood should indicate the following, at <br />Section B on the drawings: <br />a. l8 inch (or full wall widlh) verlical and 18 inch horizontal extension of galvanized sheet metal, <br />per IMC Table 308.6. <br />` 6. A rated duct enclosure is required from the point of penetratian of the floor-ceiling assembly to thc <br />outlet tenninal, per IMC section 5063.10. Catalog cuts of the rated enclosure material and installation <br />requirements classified in accordance with ASTM G 814 should be submitted with the drawings. <br />7. Gxposed duct�vrap systems in the mezzaninc storage room should be protected where subject to physical <br />damage, per IMC 5063.10, csception l. Studs and drywall sl�ould be sl�own on the drawings at the <br />mezzaninc Ievcl at thc Type I liood duct penetration. <br />8. A hinge should be indicated on the drawings at the up-blast fan for Type I hood, per IMC 50G.53, with <br />flexible, weaQ�erproof cable. <br />ENGINEERING / PUBLIC SERVICES DIVISION • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 �2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.