< <br />Ltr. D.Engelson (B0504-020) <br />April 2G, 2005 <br />Page 3 <br />,�3} The accessible toilcts should be shown to be 16" — 18" to the near side-wall. ANSi <br />Section 604.2 <br />/4)' Accessiblc toilet flush controls should be sh�wn mounted for use on thc transfer side <br />of tlte water closet (away from the near side-wall). ANSI Section 604.6 <br />�5)'The clear minimum width of the lavatory compartments should be shown at 30". <br />ANSI Section 60G.2 <br />/Gr Handr�ils should be shown on each side of the interior stainvay to tlie banquet room <br />per Section 1009.11. Details should be shown to verify compliance with the <br />requirements of Section 1009.11 <br />Pleasc provide a responsc letter, wUich shows where eaclt item in tUis correction letter is <br />addressed on tlic plan set. <br />Upon resubmission of the dra�vings, your application will be given priority and plan <br />review will begin. <br />All required suUmittals must be of sufficient detail and contain sufficient informltion to <br />ensure that the proposed structure will be constructed in compliance with all adopted <br />codes. <br />Sincerely, <br />� <br />Ton . Lce <br />Plans Examincr <br />