My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY INTERWEST BANK 2016-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
INTERWEST BANK
>
906 SE EVERETT MALL WAY INTERWEST BANK 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2017 7:50:30 AM
Creation date
2/13/2017 8:54:08 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
INTERWEST BANK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />II. �ONSTRUCTION DOCUMENTS <br />Three (3) ccmplete seu with site plans. Minimum scale: 1/8" = 1'-0". <br />✓ A. Architect's stamp. All projects of 4,000 squaze feet or more than 4 dwelling <br />units require the plans to be prepazed by an architect currently licensed w pracdce <br />in the state of Washington (RCW 18.08) - Please note that an engineer's stamp <br />does not eliminate this requirement. <br />B. Floor plan with complete dimensions (indicate entire building showing all exit <br />doors, stairs, corridors, etc.). <br />C. Building section with vertical dimensions indicating location of tenant <br />improvement, other tenants and building construction. <br />D. Wall sections indicating proposed construction and assEmbly rating as required <br />for occupancy ser<aration, azea separ.-ttion or building construction. <br />E. Stair or ramp plans (1/4" = 1'-0" minimum scale) and secdons. <br />F. Toilet room plans (1/4" = 1'-0" minimum scale) and interior elevarions indicate <br />wall and floor finishes, fixture dimensions, handicap accessories (if required) and <br />toilet accessories. <br />G. Door scheclule (indicate frame and door nting, type of lock or latch and signage <br />if requized). <br />✓ H. Lighting plan and energy budget calculations (indicate wattage of all fixtures, <br />include exterior building mounted lighdng if added or revised). This must be <br />provided at the time of building permit application. <br />� I. Energy calculations (any exterior wall or roof of existing buildings must be <br />insulated when the framing cavity is exposed when remodeling. Cavity must be <br />insulated to the maximum depth possible or to the depth indicated by energy <br />calculations). <br />� J. Structural drawings and calculations (only required if altering exisdng structure <br />or adding new load-bearing structure). <br />K. Copies of any permits/approvals issued by the Planning Department. <br />permck-c lune 70, 199 i <br />
The URL can be used to link to this page
Your browser does not support the video tag.