My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 LOMBARD AVE 2016-01-01 MF Import
>
Address Records
>
LOMBARD AVE
>
1901
>
1901 LOMBARD AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2017 4:59:03 PM
Creation date
2/17/2017 4:58:50 PM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
1901
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. _ . <br /> 4".:.+� . <br /> � g �a`I'r'�` Y ���,� ��� <br /> 3 �,+,,..,. ;j <br /> � �((� <br /> \`l/ <br /> November 29, :9S4 <br /> Jerry C. Parker <br /> 33116 SE Issaquah/Fa!I City Rd <br /> Fall City, WA 98024 <br /> Subject: Owner: Jerry C. Parker <br /> Job Address: 19Q1 Lombard <br /> Plan Check No.: 45908 <br /> Dear Mr. Parker: <br /> In responsr to yoi�r application for a constructiou permit, your plans have Ueen examined <br /> and you are advised :!:at the issuance of a permit is being withheld for the reasous listed <br /> below. These comments address buil�ing issues oniy, additional revisions or additions <br /> may be required by other departi*�ent� (cuch as Utilities, Planning or Firz). All references <br /> refer to the 1991 Uniform Buildi�g Code, as amended by the State uf Washington and/or <br /> Washington State Energy Code 1991, 2nd Edition, unless stated othenvise. <br /> 1. Provide heade� size over all openings in bearing and non-bearing walls. Specify size <br /> species and gra.de. <br /> 2. Provide one•hour fire-resistive const�uction on any garaae walls less than 10' from <br /> the e�tisting four-plex. Provide detail of one-hour fire-resictive construction. <br /> 3. Provide site plan showing distance between all buildings. <br /> 4. Provide minimum lateral re:traint panels at garage end walls. Provide detail of <br /> minimum lateral restraint par�el. <br /> 5. Grooved panel siding shall be the specified minimum thickness measured ai the <br /> bottom of grooves. <br /> 5. Specify size and spacing of anchor bolts. <br /> 7. Provide (2) #4 rebar continuous at boc[om of footing. <br /> 8. Foo[ings shall rest on undisturbed soil not less than 18" below the finished grade. <br /> Show minimum Uepth on plans. <br /> Cll'( OF E\�ERETf• 320D Cedar Street• Everett, WA 98201 • (206) 259-8802 • Fax (?.0G1 259 8859 � <br />
The URL can be used to link to this page
Your browser does not support the video tag.