Laserfiche WebLink
, <br /> September 2�, 1972 <br /> CITY OF <br /> everett <br /> Washington Mutual 5avings $8T1]C c�Tr �^�� • zs�.aeo; <br /> 3102 Colby Ev[IiETT, µ���ry�ryGTON <br /> 9Bi01 <br /> Everett, Washington 9p�o1 INGPECTIpN D[Pqq)��ENT <br /> AtCention: Mr. Thomas Brundage <br /> GenClemen: <br /> This will certify Lhat an inspecCion oi the dwelling locaCed at <br /> 2020 LomUard was made by the Housing Inspection Division and Che <br /> structure meets the minimurn requirements of tlie Uniform Building <br /> Code, Volume III except as nored below. <br /> Plumbing: <br /> 1. The discharge line from the water heater relief valve is <br /> Irapped, The discha:ge line should not rise up from flie <br /> re�:ef valve. <br /> 2. The 4" cleanout plug at the base of the stack should Ue <br /> replaced. <br /> 3. The lead bend has a temporary patch and should be <br /> repaired or replaced. <br /> 4. The clothes washer water supplies have no air chatnUcrs. <br /> �lecCrical; <br /> 1. Service inadequate. <br /> Z. I{itchen and Dining Area - Cwo groiinded uCility circuiCs needed. <br /> 3. Dinin� Area - additional outlets needed on west and souCh wall. <br /> 4. Living Room - two outlets needed on east wall. <br />