Laserfiche WebLink
� 1 <br /> 10' <br /> Existing 2x8 OF#2 on 24"ceMer on existing 4xF OF#2 beam. <br /> $, _Existing posts to be replaeed wilh new Ax9 PT pasts on <br /> 12'k12"concrete piers. G�zsset new postx with treated <br /> plywood. <br /> 25' <br /> Existing 2x8 DF 3R or better on 24"cerMer, <br /> futl span. <br /> 38'6 <br /> Orignal 6x6 OF#7 Beam to remain. Existing <br /> s to 6e rep�aced with naw 6x6 PT posts <br /> on 16'ki6"conerete piers at meximum 6'0" <br /> ceMers. <br /> Gusset new posts with treated plywood <br /> Bearing wall above cerrying ceiling <br /> joists onry. <br /> T' <br /> r Instn:!new 4x6 DF#2 cerrier beam on <br /> � � 4x4 poats en�d 12'k'12"concrete piers. <br /> New floor to be framed wHh 2x8 UF#2 <br /> ��� Front Norch �Z�0"o.c.Rotld blocked on beom. <br /> Finish floor with 3/4"T&G. <br /> Gusset new posts wilh treateA plywood <br /> F1r►mer�r�d Connie Lawe z122 Lom�ard,EaeretR Single Story,Sine�e FamiM <br /> Residence. StL^k Frame roof <br /> F�O�Qf ��1�OCt81�. with ceilinH on bearing wall <br /> down cerder of structure <br /> All Repeirs per spec's by Cily of Everett CNIP�ce direMly over existing <br /> crewl-space beam. <br /> August 5,7996 <br /> THIS SET OF <br /> DRAWINGS SHALL <br /> BE ON JOB 5lTE C17Y OF EVERETT <br /> AT Al.l. TIME�. � RFVIEWr_n ���r-, PE}�Mli� <br /> �/s/:� <br />