Laserfiche WebLink
' ( <br /> Ltr. M.Cross (B040�-003) <br /> May 24, 2004 <br /> 1'age 2 <br /> 3) The maximum spacing of the framing members sul�porting the 5/8" (�WB ceiling <br /> should be shown at 24" on cen[er (requires long dimension of GWB to be installed <br /> perpendicular to the framing). Tablc 25-G <br /> 4) The plans st�ould note [hat there �re existing (or new) anchor bol[s embedded at least <br /> 7 inches into the concrete and spaces not more than 6 feet apart. There should be a <br /> minimum of hvo bolts per plate and located not more than 12 inches (or Iess than <br /> seven bolt diameters) from each end of a plate. Section 1506.6 <br /> 5) The accessible walkway between the new meeting room and existing synagogue <br /> should be shown as Pollows: <br /> i) The width should be a minimum of 44 inches. Section 1106.4.1 <br /> ii) Thc slope should not exceed 1 vertical in 20 hoiizontal without the use of <br /> approved ramps. Section 1106.4.3 <br /> i;i) The path of travef should not pass [hrough [he parking lot area but should be <br /> directed around it. Sec[ion 1106.4.8 <br /> Please prepare a response Icucr sho�ving �vhere each item in this correctiun letter is <br /> addressed on the plan se[. <br /> Upon resubmission of thc drawin�s, your application will bc given prioriry anci plan <br /> review will recommence. <br /> .All required submi[tals m.is! be oF sufficien[ detail and contain sufficien. ir.tormation to <br /> ensure that the proposed structure �vill be :;onstructed in compliance widi all adopted <br /> codes. <br /> Sincerclv, <br /> ��Htf � <br /> T y R. Lcc ' <br /> Plans Gxaminer <br /> i]` <br /> 7 <br />