Laserfiche WebLink
" ' PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City S!andard 5601. <br /> �5;i Connect side sewer per City Standard #'s 601, 602, 604. <br /> � Connect all rooftop downspouts to the side sewer. <br /> 7. Connect rooftop downspouts to the drainage system provided tur this Iot. <br /> S. Roo(top runoff must be discharged to a roof downspout infiliration system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size lrench is 3.5'wide, 2'deep and 25' long. See atfachmenl for <br /> more details. <br /> .--.. <br /> L9J,i The contractor must meet with the Public Works Inspeclor to discuss potenlial drainage routing pr�.to <br /> beginning the pro'ect.� � <br /> 10. Install erosion control measures as determined b�the Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> I 11� Install erosion control measures per Cily of Everett Standards for small parcels <br /> ( 12. l Remove erosion control measures upon completion of the project prior to final approval of the pemiit. <br /> \ . <br /> �13. '1 All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> ✓ permilted sile. No wasfing of material is allowed on lhis building lot. <br /> ( 14.) No din, mud, rocks or debris to be tracked onlo roadway. <br /> ',15; No buildinc� materials to be stacked on sidewalks and sideH�alks to be kepl dean and open for <br /> pedestrian travel. <br /> 16. i Adjust�vater meter 6ox 1" ahove sidewalk grade. <br /> � 17.,' Remove and replace curb, gulter and sidewalk as per Cily of Evereit Standard Plan #'s 305A 8 306 on <br /> ' this proposal's frontage as directed by lhe Public Works Inspeclor (i.e. all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Install a Type I concrete driveway per City of Everett Standard #307. <br /> f��y <br /> � 19. Pave driveway from the(reat�property line out to the street paving. <br /> 20. Contact the Water District for connecting provisions for this building's water and <br /> sewer services. <br /> �� I �1; A catch basin as per Citv Standard Plan#402 with a gas trap per Standard Plan #410 i: required for the <br /> Iparking area. <br /> � 22. !r a sewer pump system is to be installed, the pressur� line must discharge into a private manhole, ihen <br /> gravity flow across the public right-of-way. <br /> 23. A sprinkler system is reGuired for this building in compliance with lhe requirements of NFDA Standards <br /> 13D. <br /> �OR PUBLIC WORKS INSPECTION, CALL RANDY AT 425-339-7403 /CLIFF AT 425-339-7404 <br /> P�.���c,n,_.,,s �'� <br /> � <br />