Laserfiche WebLink
( � <br /> , <br /> ���� puecic wo��rs <br /> July 29, 2011 <br /> ��o�lS� -Tv ..1�t' ����.r�� <br /> Kearsly Homes, Inc. <br /> 6631 Norma Beach Rd <br /> Edmonds WA 98026 <br /> Subject: Project: Gildner <br /> ]ob Address: 3225 Lombard Ave <br /> Plan Check No: C1107-006 <br /> Dear Mr. Kearsly: <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advisec� that the issuance of a permit is being withheld for the reasons listed helow. These comments <br /> address building issues only. Additional revisions or additions may be required by other departments <br /> (such as U�ilities, Planning or Fire). All references refer to the (2009 Intemational Building Code,) (2009 <br /> International Residential Code,) as amended by the State of Washington and/or Washington State <br /> Energy Code 2006 Edition, and aclopted by the City of Ev�rett, unless stated otherwise. <br /> In order for the prooessing of your application to continue, it w@II be necessary to provide <br /> the Building Division with tvuo nevv complete sets ofi drawings reflecting the corrections <br /> requestQd. <br /> �k-Z �''`�M 1� All structure supporting liviny space above the lower level unit is required to be protected with <br /> F� •P'�"� one-hour fire-resistive constriction. Sho�� how beams and posts supporting the structure above <br /> are protected. Show beams and posts on plan view. <br /> p,��L —2. Show how the existing floor framing around the stair opening is currently supported. <br /> B°`��� ' � 3. Show?r to be minimum 900 square inches and capable of encompass�ng a 30" circie measured at <br /> '` � the top of the threshold, to a point 70"above the drain. <br /> 5��i , 4. The windows shown on the elevations are a different size than the window call-out on the floor <br /> �-3 plan; please clarify. <br /> ��['� 5. Revise references of Uniform Electrical Code and Uniform Mechanical Code to the a�rrently <br /> A_ � adopted codes. <br /> �_ , 6. General notes show moximum distance between members of guardrail to be 4". The code <br /> 3��`, �- restricts the opening such that a 4" sphere cannot pass through (less than 4"opening). <br /> �7. The current energy code Chapter 6, Table 6-1 option III - Unlimited Glazing, specifies R-49 in <br /> �—` ceiling/attic vaulted ceilings R-38 and window U-value to be U-0.30 or less. Please revise plans <br /> to reflect the current requiremenG. <br /> �_Z.� 8. All habitable rooms ace required to have an aggregate glazing area of not less than 8 percent of <br /> the floor area of such rooms. <br /> .n.,.n:.....r�.,.a,..,..�v��n�rw,n»c i,..,n..n n�-�� <br />