Laserfiche WebLink
�� <br />� <br />8. Above grade walls in the exis;ing basement are required to be insulated to the <br />maximum depth of the freming cavity (R-21 in 2x6, R-15 in 2x4). <br />9. Chimneys are required to project a minimum of 2'-0" above structures within lu'-0". <br />Show requirement on plans. <br />Please prepare a response letter showing where each item in this correction letter is <br />addressed on the pian set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain su�cient information to ensure <br />that the proposed structure will be constructed ir� compliance with all adopted codes. <br />Sincerely, <br />/�.��,�.� <br />Jeff Heiliran <br />Development Technician <br />425-257-897G <br />Email: jheilman o-ci.evere�t.w� us <br />S�.VCrr��monAC-e��:afUlie'�-�a�AC12C3-011 (G529 LomCard Aee-doC <br />