Laserfiche WebLink
Septembar 14, 1972 <br />Capic�l Mortgnge 6 Eecrow Co., Inc. <br />P. 0. IIox 1052 <br />Everett, Wuehington 98106 <br />evere� <br />„ <br />Gentlemen: <br />This will certify thaC an inapection of the dwelling locuted at <br />SG20 Lowell P.oad �oae made by the Housing inspection Divieion and <br />the etructure meete the minimum requirements of the Uniform <br />Building Code� Volume III except as noted beZow. <br />Plumbing: <br />1. The water heater relief valve ie not a code approved typa. <br />2. Thia eink ia noC vented, <br />3. The waete nnd vent piping for Lhe toilet, lavatory, and bathtub <br />does not comply with the code, <br />Electrical• <br />1. Verify servic3, hns not been permanentiy cennected by PUD. <br />2. Kitchen uad din'ng urea two grounded utility circuits needed, <br />3. Additional outlets needed, Icitchen west counter epace and east <br />wall, dining room on crest and easC wall. <br />4. Bnthroom grounded outlnt neaded, light to be grounded also. <br />5. Hot water tank to 6e on ¢10 wire. <br />6. Upstaire south bedroom outlet needed on weat wall. <br />7. Upetaira north bedroom outlete needed on north aad aaet wall. <br />8. All wiring to comply with NGC 410-95 (grounding). <br />9. All grounded type outlete to be grounded. <br />