Laserfiche WebLink
Tel: 206.547.0100 <br />NVL Labaratories, Inc. Fax: 206.634.1936 <br />4708 Aurora Ave. N., Seattle, WA 98103 <br />Bulk Asbesi�os Fiber Analysis <br />� Client: GLogics,lnc <br />Address: 1321-254th Placr, SE. <br />Sammamish, WA 96075 <br />� Attn.: Mr. Rory Galloway <br />Project: Everett FS 5 <br />Lab ID #: 20092146 Client Sample #: 1-12-1 <br />SamPle Location: Everett FS 5 <br />Description: Black/tan brittle material with paint <br />OTHER FIS�20US MATERIALS: <br />Cellulose 3%, Glass fibere 5% <br />ASBESTOS 'L'2'PE: <br />*None Detected <br />Lab ID #: 20092147 Ciient Sample #: 1-13-1 <br />NVLAP <br />1Y102063 <br />NVL Batch Number. 00-11598.00 <br />Client Projed M: O1-0105-A <br />Number of samples: 4<i <br />NON-FIBROUS MATERIALS: <br />Binder 6c filler, Paint <br />PERCENT <br />ND <br />Sample Lacation: Everett FS 5 <br />Description: LAYER 1: White powdery material, LAY&R 2: White cha(ky material with paper <br />OTHER FIBROUS MATERIALS: <br />LAYER 1: Cellulose 4% <br />LAYER 2: Cellulose 25% <br />ASBESTOSTYPE: <br />LAYER 1: "None Detected <br />LAYER 2: *None Detected <br />Lab ID #: 20092148 Client Sample #: 1-13-2 <br />Sample i.ocation: Everett FS 5 <br />Description: Tan fibrous material with coating and paint <br />NON-FIBROUS MATERIALS: <br />LAYER 1: Binder & filler <br />LAYER 2: Binder 6c filler, Gypsum/binder <br />PERCENT <br />ND <br />ND <br />OTHER FIBROIIS MATERIALS: NON-FIBROIIS MATERIALS: <br />Cellulose 70% � Binder & filler, Paint <br />ASBESTOS TYPE: PERCEIVT <br />*None Detected ND <br />(Sample results are continued on the next page.) „ <br />Sampled by: Client <br />Analyzed by: Wei Long Tai <br />Reviewed by: Nick Ly <br />Date: 09/18/2000 <br />Date: 09/18/2000 <br />Note: If samples are not homogencous, then subsamples o( �he mmponents were analyzed sep�amples are analyzed using EPA <br />600/R-93/116 Method with the tollowing measurement unceAainties (or the reported % Asbestos (1%=>0.3%, Sq =>I-9%, 10%=5-15%, 20Y,.=10.30%, <br />50%=40-60%). '[his report relates only m the items tested. If samples were not milected by NVL personnel, then the accvracy of the results is limited <br />by the methodology and acuity ot the sampie rnllectoc This report shall not be reproduced ezcept in full, without written approval of NVL <br />Laboratories, Inc. It shall not be used to daim product endorsement by NVLAP or any other agenq� o( the US. Govemment. <br />Page 7 <br />