Laserfiche WebLink
Tel: 2`J6.547.0100 <br />NVL Laboratories, Inc. Fax: 206.634.19�6 <br />4708 Avrora Ave. N., Seattle, WA 98103 <br />NVLAP <br />Bulk Asbestos Fiber Analysis #102063 <br />Client: G-Logia <br />Address: 1321254th Place SE <br />Sammamish, WA 98075 <br />Attn.: Mr. Rory Galloway <br />Project: Everett FS 5 <br />Lab ID #: 20092173 Client Sample #: 3-1-1 <br />Sample Location: Everett FS 5 <br />Description: 1„pYER 1: Beige vin� t with brown streaks LAYER 2: Black asphalHc mastic <br />OTHER FIBROUS MATERIALS: <br />LAYER I: •None Detected <br />LAYER 2: Cellulose 4% <br />ASBESTOS TYPE: <br />LAYER 1: •None Detected <br />LAYER 2: *None Dete:ted <br />NVL Batch Number. 00-11599.00 <br />Client Project M: O1A105-A <br />Number of samples: 43 <br />NON-FIBROUS MATERIALS: <br />LAYER 1: Vinyl/binder <br />LAYER 2: Asphalt/binder <br />PERCENT <br />ND <br />ND <br />Lab ID #: 2(J092174 Client Samplx #: 3-1-2 <br />Sample Location: Everett FS 5 <br />Description: LAYER 1: Beige vinyl with brown streaks LAYER 2: BI-.ck asphalHc mastic <br />OTHER FIBROIIS MATERIALS: <br />LAYER 1: "None Detected <br />LAYER 2: Cellulose 4% <br />ASBESTOS TYPE: <br />LAYER 1: "None Detected <br />LAYER 2: •None Detected <br />NON-FIBROIIS MATERIALS: <br />LAYER 1: Vinyl/binder <br />LAYER 2: Asphalt/binder <br />PERCENT <br />NA <br />ND <br />Lab ID #: 20092175 Client Sample #: 3-2-1 <br />Sample Location: Everett FS 5 <br />Description: LAYER 1: Tan surfaced brown n�bbery material LAYER 2: Brown brittle mastic <br />OTHER FIBROUS MATERIALS: NON-FIBROUS MATERIALS: <br />LAYER 1: Cellulose 3% LAYER I: Rubber/binder <br />LAYER 2: Cellulose 3% LAYER 2: Mastic/binder <br />ASBESTOS TYPE: PERCENT <br />Sampled by: Client <br />Analyzed by: Steve Zhang <br />Reviewed by: Nick Ly <br />Date: 09/18/2000 <br />Date: 09/18/2000 <br />Note: If samples are not homogeneous, then subsamples of the mmponents were analyzed separa e�y. FbGtk samples are analyzed asing EPA <br />600/R•93/116 Method rvith the tollowing measurement uncenainties for the reported % Asbestes (1%=>0-3%, 5%=>1-97, 109'o=S15%, 20%=70-3050, <br />50 %=40.60%). 'Ihis report relates only lo the items tested. I( samples were not mllected by NVL personnel, then the accura�y of lhe results is limited <br />by the methodology and acviry of the sampie mllector. 'lt�is repoA shall not be reproduced except in full, without wriften approval of DIVI. <br />Laboratories, Inc It shall not be used to claim product endorsement by M�[.AP or any other agency of the US. Govemment. <br />Fage 1 <br />