My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1600 MADISON ST 2016-01-01 MF Import
>
Address Records
>
MADISON ST
>
1600
>
1600 MADISON ST 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 11:00:36 AM
Creation date
2/17/2017 9:51:17 PM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
1600
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
565
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
management objectives of the City. As with the development of any site, if a previously <br />unidentified environmental condition is encountered during site work, these environmental <br />issues should be evaluated and addressed, if necessary, at that time. <br />Recammendations jor Site Redeve%pment: Based on mapping information provided to <br />G-Logics, the planned replacement building will cover the area recommended for over <br />excavation. As such, foundation-design considerations should include appropriate <br />modifications for the proper control of backfill and compaction in this area to reduce the <br />potentia] for settlement damage to :he new fire station structure. <br />8.0 LIMITATIONS <br />Site contamination explorations aze non-comprehensive by nature and aze unlikely to <br />identify all environmental problems or eliminate all risk. This report is a qualitative <br />assessment. G-Logics offers a range of investigative and engineering services to suit the <br />needs of our clients, including more quantitative investigations. Although risk can never be <br />eliminated, more detailed and extensive investigations yield more information, which may <br />help to better understand and manage site risks. Since such detailed services involve greater <br />expense, we ask our clients to rarticipate in identifying the level of service t6at will provide <br />them with an acceptable level �f risk. Please contact the signatories of this report if you <br />would like to discuss this issue of risk further. <br />The scope of work on this project was presented in our identified workplan and <br />subsequendy approved by you as our client. Please be awaze oL: scope of work was limited <br />to those items specifically identified in the workplan. Other activities not specifically <br />included in the presented scope of work (in a workplan, correspondence, or this report) aze <br />excluded and aze therefore not part of our services. G-Lo3ics also performed this <br />environmental exploration in accordance with the guidelines sat forth in the American <br />Society for Testing and Materials (ASTM) Standard Practice for Environmental Site <br />Assessments: Phase II Environmental Site Assessment Process. <br />Land use, site conditions (both on-site and off-site), and other factors will changc over time. <br />Since site activities and regulations beyond our control could change at any time after the <br />completion of this report, our observations, findings, and opinions can be considered valid <br />only as of the date of the site visit. <br />OIAIO�� -RT.doc � �{ 9/v�(��J <br />Copyright 2001 G•Logics, Inc. Page IJ of 14 �'� � <br />
The URL can be used to link to this page
Your browser does not support the video tag.