My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1600 MADISON ST 2016-01-01 MF Import
>
Address Records
>
MADISON ST
>
1600
>
1600 MADISON ST 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 11:00:36 AM
Creation date
2/17/2017 9:51:17 PM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
1600
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
565
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />� <br />Mr. Chris Lark <br />Febniary 20, 2001 <br />Based on the measured standard penetration resistance values, the on-site soils are sufficiently <br />� dense tha[ the polential for earthquake induced soil liquefaction is considered to be vcry low. [n <br />addition, based on existing information, the site is not underlain by any known active fault. <br />Therefore, ground rupture from faulting and liquefaction are not design consiclerations for this <br />� project. <br />p 5.2 FOOTINCS <br />� <br />Conventional spread footings bearing direcUy on the underlying glacial till or a structural fill <br />extending to the till are recommended for lhe suppoR of the new fire stalion. The footings <br />�_ should be designed based on a maximum allowable bearing pressure of 3,000 psf that may be <br />increased by 1/3 for transient conditions such as wind and seismic loadings. All exterior footings <br />u shouid be iounded a minimum dislance of 18 ir,ches Uelow the adjacent finished grade, and all <br />t interior footings should be at least 12 inches below the top of floor slab. <br />1_ <br />� <br />Lateral forces resulting from wind or seismic events may be resisted by a combination of sliding <br />resistance a[ the footing base and passive earth pressurc against the buried portions of the <br />structure. A coefficient of friction of 0.5 may be assumed between dre Uase of the footings and <br />the bearing surface. Passive soil resistance against lhe sides of buried foolings can be estimated <br />using an equivalent (luid unit weight of 500 pounds per cubic foot (pcQ assuming that the <br />Uackfill against tlte foo!ings consists of granular structural fill compacted to 95 percent of the <br />maleriaPs maximum dry density, detem�incd using ASTM D1557 (Modified proctor). The <br />recommended passive resistance includes a factor of safety of about 1.5. <br />All footing excavations should be trimmed neat and the bottom of q�e excavation should be <br />cazefully prepazed. The footing excavations should be observed by an engineer from our firm <br />� prior to placing steel and concrete, to verify that dte recommendations of this report have been <br />followed, and that an appropriate bearing slratum has been exposed. Tot :i and differential <br />settlements of footings designed and constructed in accordance with our recommendations are <br />� anticipated to be within tolerable limits. Under static loading, we estimate that the spread <br />footings may experience total settlemenls of less than about %Z inch. Differential settlements <br />between two adjacent load-bearing components supported on competent soils are expected to be <br />. less than about Y< inch. <br />� 5.3 CONCRETC SLA[3-ON-GRADE <br />Interior slab-on-grade floors should be provided with an adequate moisture breal:. The capillary <br />� break should consist of a minimum of 6 inches of &ee-draining, crushed rock or �vell-graded <br />sand and gravel wliich is compacted to a firni and unyielding condition. We recommend that the <br />�capillnry break material have a maximum partide size of'/a inch, with no more than 80 percent <br />, passing the No. 4 sieve and less than 5 pement passing the U.S. Stanclard No. 100 sieve. In areas <br />00-04G-100 Geotcch Report 4 PanGEO, Inc. �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.