Laserfiche WebLink
_. �. ����: ,�„ ,,,.,.,,��� „� ,.,v �,...� ..,.�,.�,.,.,,�.,v���s v,.,,... .,.�....,....� ..�..�..� ��.-���x,�...___..,...,. �..... <br />and serving as a landing. �he bo�com or rop riur may be rcduced along �he slape to Icss than a����s 00? mm) <br />� inheightwi�hthevariationinheightohhebonomoitopr,�ernatcy—ceM;inches(76mm)inevcry3feet <br />� (914 r n( smirway wid�h. . . � 1 . . . ,. • <br />\ <br />IOOG.4 4VinAin� Slairways. In Group R, Division 3 Occupancies and in private stairways in <br />Group R, Division 1 Occupancies, winders may be uud if the required width of run i; provi�ed at a <br />point not more than I2 inches (305 mm) from the side of the staieway wherc the trcads are nartower, <br />but in no case shall any widih of run 6e lcss than 6 inches ( I52 mm) at any point. � <br />1006.5 Circular Slairways. Circular swirways may be used az an exit, provided the minimum <br />width of run is not less than (0 inches (254 mm) and the smaller radius is not less than twice the <br />widih of the stairway. 71u largest tread width or riser height within any flight of stairs shall not ex- <br />ceed the smallest by morc th. n�/g inch (9.5 mm). � � � <br />1006.6 Spiral Stairways. In Group R, Division 3 Occupancies nnd in private stairways within <br />individual units of Group R, Divisiun I Occupa�:cies, spiral stairways may be installeQ: Such stair- <br />wa/s may be used for required exits when �he area served is limited to 400 squarc (eet (37.16 m'-). <br />Ttie tread must provide a clear walking area measuring at le�st 26 inches (660 mm) fmm the omer <br />edge of the supporting column to the inner edge of tho handrail. A run of at least 7�/z inches ;191 <br />mm) is to be provided at a point 12 inches (305 mm) Crom where the tread is �he nanowest. The rise <br />must be sufficient to provide 6-foot 6-inch (1981 mm) headroom. Tt�e rise shail not exceed 9�/, <br />inches (241 mm). � � <br />1006.7 Landings. Ev-..y ianding shnll huve a dime��ion measured in the direction o( travcl not <br />less than the width of the stairway. Such dimension nred �ot excecd 44 inches (� I I8 mm) w!�en �he <br />stairhas a straight run. Thero shall not be mare �han :2 fer.t (3658 mm) venically betwcen landings. <br />For landings with adjoining doors, see Section 10.'14.1G. -. . <br />F.XCEP7'ION: Slain serving an unoccupicd iwt e¢ eaempt from lhese provisions. � <br />1006.8 Qasement Stairways. When a basement stairway aad a stairway to an upper stury termi- <br />nate in the same exit enclo;ure, an approved barrier shall be provided to prevent persons from con- <br />ti:ming on into the basemen[. Directional exit signs shall Ix providcd as specified in Section7013. <br />i006.9 .Fiandrails. Stain�ays shall have handrails on each side, end every staineay required to be <br />more than 88 inches (2235 mm) in wid!h shall tx provided with no[ less than one intermediate hand- <br />rail Cor each 88 inches (2235 mm) of � equired width. lntermediate handrails shall be spaced approx- <br />imately equally across with the entire wirth of the stainvay. . . �� <br />EXCEP'CIONS: I. Stairweys less inan 44 inche; (1118 mm) in width or stairHays ecrving one individual <br />dwelling unit in G`oup R, Civision 1 or 3 Occupancits or a Group R, Division 3 cor�grcgote rcsid<nce may <br />� have one handmil. � � - � ' • � � <br />� 2. Private stairways 30 inches (762 mm) or less in height may have bandrails on one si3e only. � <br />3. Siairways having less ihan four riscrs nnd urving one individual dwelling unit in �iroup R, Divisioi I <br />, or3,oraGroupR,Division3congmgalercsidenceotservingGroupUOccupanciesn«dnothavehandrails. <br />The top of handrails and handrail extensions shall be placed no[ less than 34 inches (864 mm) or <br />more than 38 incf�es (965 mm) above the nosing of treads and landings. Handrails shal! be continu- <br />1-182 <br />1994 UNIFORM BUILDING CODE 10Q6.9-1006.15 <br />ous the full length of the stairs und, except for private stairways, at least one handrail shall extend in <br />ihe direction of the stair run not Iess than 12 inches (305 mm) beyond the top riser nor less than t2 <br />inches (305 mm) beyond the bottom risec Eads shall be rewmed or shall tertnina�e in newel posts or <br />sa(ety tcrniinals. � <br />The handgrip ponion of handrails shall not bc less than I�/q (32 mm) inches nor more than 2 in- � <br />ch�s (S 1 mm) in cross-sectional dimension or the shape shall provide an equivalent gripping sur- <br />fnee. The handgrip ponion of handrails shall have a smooth surface wiih no shary comers. <br />H:mdrails projecting from a wall shall huv<a space of not less than I�/, inches (38 mm) ben��cen <br />the wall and thc handrail. <br />100fi.10 Cuardrails. Smirways open on one or both sides shall have guardmils as required by <br />ScrrOon IOOI.S. <br />1G';.11 ProteclionofExterior�VallOpenings. ExceptinGroupR,Di�•ision30ccupancies,all <br />openings in the ex�erior w�all below and within 10 fcet (3Q38 mm), meawred horizontally, of an <br />exterior cxit stairway or unprorected openings in an imerior exit stairway serving a building over <br />t�co sieries in hzight or a iloor level having such openings in t�vo or more �uors below shall bz pro- I <br />tected by fised, self•closing, or automatic-clusing fire assemblies havins athme•founhs-hour fire- <br />pro�action rating. � <br />ESCE('TIO�S: I.Openings may tx unpwtened whrn tH�o separalcd eilcrior stairwn)'s sen�e an uterior <br />exit b�lcunv. <br />2. Proiec�ion of openings is nm rcyuircd for open parking garages conformine m S.ciir � JOS. <br />1006.1? [nterior Strire�oy Conslruction. Intrrior stainvays shall be conswcted as specified in <br />Sections 602.4. 603.4, 60-1.4, 605.4 and 606.4. 5�$ <br />Escapt �ahan enclosed wable spacz under stairs is prohibited by Stciion 1009.6, �he walls and <br />soltits of Ihe endu<eJ snace sh:�ll hr mntec�rd on �he enclo.ed siJc as rtouirad for one-hour firc- <br />