Laserfiche WebLink
INSPECTION DEPARTMENT. <br />C)T.Y .OF. EVERaT <br />Jurisdictionof................................................................................ <br />GENERAL PLAN CORRECTION LIST <br />�j� �,�j��t)ased on 1967 Edition of the Uniform Building Code -0 " <br />Gwrer..... ........................ ............................. Plan Check No..... � 52....Valu/at�io/n........................ <br />Job Address... l!2�.....Q � r/ '�T•.. <br />.................... �p .....a :..> :....... j ...V.T ................... <br />Type of _ AlOccupancy G <br />City ..... .................................................. <br />.................................................. Construction .... `.5.................. Class jfication...... 1......... ` .... <br />State.............1................................................................ Fire Zone No........ ........... Stories ............�r........ .. . <br />Total Allowable Floor Area .............. <br />Basis for Increase <br />Ft. Floor Area: 7'/,v v 1' : /0 p <br />:f.......... ........................ .................... ................ ... ..... .... <br />. <br />.................. ......................................................... <br />COMMENTS OR ASSUMPTIONS: <br />Floor (Max.) .................................................... _Sq. Ft. <br />Floor (Total) .. ............. jf ......... _ ..,Scl. Ft. <br />Occupant Load .................... <br />�l+q.OD.. <br />f 14 <br />11 <br />C9rrections checked below are to be made on plans before permit Is Mued. <br />The approval of plans and spe6ications does ,not permit the violation of any section of the Building Code, or other City Ordinance or <br />Stote Law. <br />GENERAL <br />1. <br />Valuation should beb................................ <br />2. <br />Show job address on plans. <br />m <br />3. <br />Give name of person responsible for plans. i <br />4. <br />Submit fully dimensioned plot plan. <br />5. <br />Give all dimensions on plot plan. <br />AREA LIMITATIONS AND GENERAL <br />OCCUPANCY REQUIREMENTS <br />6. <br />Ground elevations should be shown at comers <br />of the building and at changes in ground slope. <br />The ground elevations should be taken at the <br />14 <br />lowest point between the exterior wall and a <br />it <br />FF <br />point 5 feet out or at the property line, <br />1.4 <br />closer. Where the exterior wall is parallel to and <br />within 5 feet of a public sidewalk, alley, or <br />w <br />other public way the ground elevations should <br />be the elevation of the public way. The number <br />of stories in this buildin•- cannot be determined <br />1 <br />until this data is furnished. <br />7. The total floor area is limited to .......................... <br />square feet. Sections 505 and 506. <br />8. Unobstructed yards of ...................... feet should <br />be maintained on .... _............................. sides <br />of the building for area purposes. Section 5C6. <br />9. Pruvida uu:ails to eho.v Cna1 .. _.... <br />.hour Area separation walls should Comply with <br />Section 505 (c). <br />(a) Extend vertically from the foundation to a <br />point 30 inches above the roof. <br />(b) Total width of all openings limited to 25 per <br />cent of the wall length in the story under <br />consideration. <br />(e) All openings protected with fire assemblies <br />having a fire -resistive rating of one -and -one- <br />half (three) hours. <br />(d) Ducts through area separation walls should <br />be avoided. It allowed, fire dampers on each <br />side of the wall are required. Section 30.102, <br />U.B.C. Standards. <br />10. A fire -resistive occupancy separation L conform- <br />ance with Table No. 5•B and Sectior 503 is <br />required between the <br />................................................ hours) .. ............• <br />.................................................. ............ hours) <br />.................................................. (............. hours) <br />it. Horizontal occupancy separations should be sup- <br />ported with a structural system having equiva• <br />lent lire -resistive protection. Section 503 (d). <br />12. The building is limited to ........................ stories <br />(...................... feet in height) as a Type .......... <br />structure. Section 507 and Table No. S.D. <br />I TYPE OF CONSTRUCTION <br />13. Type V (III-N) (IV•N) buildings are ,cat permitted <br />in rice Zone No. 1. Scctmn IE02 (a). <br />14. Roof coverings should be fire retardant. Section • <br />1603 (a) or 1704. Details or spr-cificarions com- <br />plying with Section 3203 (c) are required. <br />Sheet No ...... .t...... of ........ A ......... Sheets <br />