Laserfiche WebLink
Towner\Schuld\Canfield <br />CONSULTING CIVIL ENGINEERS <br />5122 Sound Avenue <br />October 21, 1996 <br />Everett, WA 9820's <br />Robert and Heidi Packer <br />1209 Madrona <br />Everett, WA 98203 <br />Subjeet: Project No. C96130 <br />1209 Madrona <br />Modifications to existing structure <br />Dear Mr. and Mrs Packer: <br />a Limited Liability Company <br />L-xperienced in Design and Engineoring of Siructures <br />206-308-4�08 FAX:206-513-8078 <br />�D ����d� � <br />2 a 1996 <br />............. ��,7,�..�....:,,,,..... <br />CITY OF EY�RETT <br />Bldg. Petrrllt E6JLflt(dr <br />Pursuant to your instrucfwns, we have i�vesligated lhe structural effects of architectural moditicafwns to <br />the existing residence located at 1209 Madrona. <br />The subJecl structure Ifes in an area whkh requires ihat new siructures be designed Sor an 80 mph wind, <br />using exposure'C'. The lateral-force-resisting system of the existing stnicture falis well below'i', <br />strength required by those criteria. It is also incapable of withstanding current seisrr�c design fo�.::s. <br />It is our understanding that you dosire to make ihe following mod'rfications: <br />1. Eliminate the wall panel between ihe small windows in west wall of the dining area. <br />2. Place a doorway from the stairwell on the main level into the study. <br />3. Place a patio door in ihe noAh wall of the basement. <br />4. Widen the opening between the living room and the dining room on the main level. <br />5. Remove the northemrtrost column line from the basement wflh minimum loss of headroom. <br />Any reduction in wali area or floor area, wflhoul rei�forcing ihe adjacent structural elements, reduces the <br />sirength of the buiiding. The following is an excerpl irom SeclEon 3403 of the 1994 Uniform Building <br />Code: <br />'Addilions or aflerations shall rwl be rr�ade to an existing building or structure when such existing <br />buikling or stnicture is rwt in full compliance with the provisions of this code except when such <br />addilion or atteratpn will resuft in the existing buikling or structure being no more hazardous <br />yased on I'rfe safety, firesafety, and sanitation, than before such addRbns or afterations are <br />underlaken. <br />Ezeaption: Afterations of existing struclural elements, or additions of new structural <br />elements, which are not required by Section 3401 and which are initiated for the purpose of <br />increasing the lateral-force-resisUng strenglh or stiffness of an existing structure need not be <br />designed for forces conforming to these reg�lalbns provided than an engineering analysis is <br />submitted to show that: <br />1. The capacity of existlng siruclural elements required to resisl forces is not reduced, and <br />Page 1 of 3 <br />