4. <br />v <br />6. <br />� <br />� <br />a <br />16. <br />� <br />� <br />PUBLIC WORKS PERMIT COMMENTS <br />Connect side scwer per City Standard #601. <br />Connect side ser�er per City Standard #'s 601, 60 �, 604. <br />Connect all roo(top downspouts to the side sewer. <br />Connect rooftop downspouls to the drainage sys,em provided (or this lot. <br />Rooftop runoff must be discharged to a roof do,vnspoul in(iltration system per City o( Everelt Storm <br />Manual 3-2.6.2. The approximale size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />The contractor must meet with the Public Works Inspector to diswss potent�al drainage routing prior to <br />beginning the project. Call Randv Allen a: 425•339-7403 // Cail Cliff Lindman at 425-339-7404. <br />Install erosion conlroi measures as determined by the Public Works inspector, such as silt (ence, sfrav� <br />bales, s�vales, or erosion blankets. <br />inslall erosion control measures per City ot Everett Standards for small parcets <br />Remove erosion control measures upon completion of the project prior to final approval oF the permit <br />All excavated materiai from foundation, sidewaik and driveways shall be hauled to an approved, permitted <br />site. No was�ing of material is allowed on Ihis building lot. <br />No dirt, mud, rocks or debris to be tracked onto roadway. <br />No building materials to be stacked on sidewalk/roadway and sidewalk/roadway to be kept clean and <br />open tor pedestrian travel. <br />Adjust water meler box 1" above sidewalk grade. <br />17. Remove and replace curb, gulter and sidewalk as per Ciry oi Everett Standard Plan tl's 305A 3 306 cn <br />this proposal's frontage as directed by the Public Works Inspector (i.e. all unused driveways and ary <br />broken or damaged area must be replaced). <br />1�—Install a Type I concrete drivewayper City o( Everelt Slandard #307j� �� p✓f '-$>¢Et'�vr��L <br />19 Pave driveway from the (ront property line out to the slreet paving. <br />20. Pave lo exisling paving in alley. <br />21 Contact the _ Water Disiricl (or connecling provisions for this building's water and <br />sewer services. <br />22. A caich basin as per City Siandard Plan #402 with a gas trap per Standard Plan #410 is required (or the <br />parking area. <br />23. <br />24. <br />If a sewer pump system is to be installed, the pressure line musl discharge into a privale manhole, then <br />gravity flow across the public right-of-way. <br />A sprinkler system is required for this building in compliance with the requiremenls of NFPA Standards <br />13 D. <br />Your Public Works Inspector is Cliff Lindman. Call him at 425-339-7404 for questions and inspections <br />PWCommenfs I Revised 618117 <br />�v <br />