Laserfiche WebLink
�eotechnical Engineenng P.epart <br />1313 Madrona Avenue <br />Everett, Washington <br />March i l, 2013 <br />RN File No. 2793-001 A <br />Page 7 <br />Foundations <br />Conven[ional shallow spread foundations should be fourded on undisturbed, medium dense or <br />firmer soiL If the suil at the planned bottom or footmg elevation is not suitable, it should be <br />overexcavated to expose surtable bearing soil. Footings should extend at least 18 inches belo� <br />the towest adjacent finished ground surface for frost protecUon. Nlinimum foundation widths <br />should coniorm to IBC requirements. Standing v✓ater should not be allowed to accumulate in <br />!ooting trenches. All loose or disturbed soil should be removed irom the f�undation excavation <br />prior to plaang concrete. <br />For foundations constructed as out6ned above, we recommend an allowable design bearing <br />pressure of 2,500 pounds per square foot (psf� be used for the iooting design. IBC guidelines <br />should be followed when considering short-term transitury :vind or seismic loads. Potenval <br />foundation settlement using the recommended allowable bearing pressure is estimated to be <br />less than 1-inch total and 'fi-inch differential between footings or across a distance of about 30 <br />(eet. Higher soil bearing values may be appropriate with wider fooungs. These higher vaiues <br />can be determine�+ after a review of a specific design. <br />Lateral Loads <br />The lateral earth pressure acting on retaining walis is dependent on the nature and density of <br />the soil behind the wall, the amount of lateral wall movement, which can ocr,��r as backfill is <br />placed, and tne inclination of ihe backfill. Walls that are free to yield at least one-thousandth of <br />Ihe height of the wall are in en "active" condition. Walls restrained from movement by <br />sUffness or bracing are in an "at-rest" condition. Active earth pressure and a[-rest eanh <br />pressure can be calculated based on equivalent fluid density. Equivalent flwd dens�t�es for <br />ac[ive and at•res[ earth pressure of 35 pounds per cubic foot (pc0 and 55 pcf, respectively, may <br />be used for design for a level backslope. These values assume that the on-sde soils or <br />imported granular fill are used for backfill, and that the wall bac4;fill is drained. The preceding <br />values do not include the effects of surcharges, such as due to foundation loads or other <br />surface loads. Surcharge e(fects should oe considered where appropriate The above drained <br />acUve and at-rest values should be increased by a uniform pressure of 6.3H and 19JH psf, <br />respectively, when considering seismic conditions using 2009 IBC. The above drained acuvc. <br />and at-rest values should be increased by a undorm pressure oi 7.4H and 22.7H psf, <br />respectively, when considering seismic conditions using 2012 IBC. H represenis ihe wall <br />height <br />The above laterai pressures may be resis[ed by fnction at the base of the wall and passive <br />resistance against the (oundation. A coe(ficient of fnction o( 0.45 may be used to determine <br />[he base (riction in the native glacial soils An equivalent fiuid densiry of 795 pcf may be used <br />for passive resistance design. To achieve Ihis value of passive pressure, the foundations <br />should be poured "neat" against the nati�•e dense soils, or compacted fili should be used as <br />backiill against the front of the footing, and the soil in front of the wall should extend a <br />horizontal distance at least equal to three times the foundalion depth. A factor of safety of 1.5 <br />has been applied to Ihe passive pressure and the friction coefficient to account for required <br />movements to generate '. •:se pressures. <br />Robinson Noble, Inc <br />