PUBLIC WORKS PERMIT COMMENTS <br />L% Connect side sewer per City Standard #601. <br />5. Connect side sewer per City Standard #'s 601, 602, 604. <br />6. Connect all rooftop downspouts to the side sewer. <br />7. Connect rooftop downspouts to the drainage system provided for this lot. <br />8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br />Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />9. The contractor must meet with the Public Works Inspector to discuss potential 9rairage routing prior to <br />beginning the project. <br />10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br />bales, swales, or er: sion blankets. <br />11 Install e..)sion control measures per City of Everett Standards for small parcels <br />12. Remove erosion control measures upon completion of the project prior to final approval of the permit. <br />13 All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br />permitted site. No wasting of material is allowed on this building lot. <br />44. No dirt, mud, rocks or debris to be tracked onto roadway. <br />40,v- " iAvw*Y <br />15.) No building materials to be stacked on s4ewe4ks and sidewefks to be kept clean and open for <br />Pedeatnart travel. <br />Ve- 9 lei <br />16. Adjust water meter box 1" above sidewalk grade. <br />17. Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan #'s 305A & 305 on <br />this proposal's frontage as directed by the Public Works Inspector (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />18. Install a Type 1 concrete driveway per City of Everett Standard #307. <br />19 Pave driveway from the front property line out to the street paving. <br />20. Contact the Water District for connecting provisions for this building's water and <br />sewer services. <br />21. A catch basin as per City Standard Plan #402 with a gas trap per Standard Plan #410 is required for the <br />parking area. <br />22. If a sewer pump system is to be installed, the pressure line must discharge into a private mp.nhole, then <br />gravity flow across the public right-of-way. <br />23. A sprinkler system is required for this building in compliance with the requirements of NFD.4 Standards <br />13D. <br />FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 425.339-7403 I CLIFF AT 425-339-7404 <br />PW'Com,mnts � I <br />