Laserfiche WebLink
' � Washington State Energy Code: Component Performance Worksheel,Type R3 Occupancies <br /> HAAS<BROTHERS HOMES <br /> c�ac��-���b <br /> Heating System Size <br /> Ducts are located ic unoc�iditioned spa� - <br /> iso�.' <br /> Conditioned FloorArea 1943 Equipmeni s�ze over design load - JO <br /> Conditioned Building Volume 15544 Btu/hour outpul 121.895 <br /> � KW 357 <br /> Weather Statioi���arys��ue <br /> Proposed Design Values <br /> Gomponent Performance,R3 occupancies Code Target Values q�ea UA <br /> Area UA <br /> Vertical Glazing U = 0.300 291 87.4 310 867 <br /> Overhead Glazing U= 0.500 0 0.0 0 QO <br /> Doors U = 0200 18 3.6 t8 ` g <br /> FlaWaulted Ceilings U = 0.027 1332 36A �332 4� 3 <br /> Wall (above grade) U= 0,056 22970 1286.3 22952 117o E <br /> Floors U = 0.029 685 19.9 685 �"� <br /> Slab on Grade F= 0.360 0 0.0 0 0.0 <br /> Below Grade <br /> 2'depth,wall U= 0.042 0 0.0 0 0.0 <br /> 2'deplh, slab F= 0.590 0 0.0 0 0.0 <br /> 3.5'depth,wall U= 0.041 0 0.0 0 0.0 <br /> 3S'depth, slab F= 0.640 0 0.0 0 0.0 <br /> 7'depth,wall U= 0.037 C 0.0 0 0.0 <br /> T depth, slab F= 0.570 0 0.0 _ 0 0.0 <br /> Targel UA Total 1433.1 Proposed UA lblal 13212 <br /> Target Credits from Chpt.9 1.0 Proposed Ccedits from Chpt.9 1.0 <br />'� If the Proposed UA s the Target UA, and ihe Prop�sed Credils Rom Chpt. 9 are>_ t Rian ihe home meets th2'2009 Vt'SEC. <br /> Check othercodereqwremen�s <br /> Ccp��n,i.t -� � l:'Sl1E f I :[�J(��Veic �n IO)CCp�=tl�y Ferm�ssion fran Waslun�lcn State UnFvarsity E.tenson Ener�y Program �see copy i9ti��s�ncl������� <br /> � <br />�,... <br />-i'r.P,. __ _— <br />":�x.. _ <br /> �, <br />