My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8620 HOLLY DR 2018-01-02 MF Import
>
Address Records
>
HOLLY DR
>
8620
>
8620 HOLLY DR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/25/2023 7:09:34 AM
Creation date
2/18/2017 11:52:13 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
8620
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( <br /> Plans for such system shall be submitted [o the Fire Marshal for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended frn use. <br /> Appropriate trip lests, witnessed by a Fire Department inspector, shal] be perfom�ed, along <br /> with a certiricate of completion, prior to fnal acceptance of tbe system. <br /> Fire alarm systems shal] be installed according to NFPA Siandard 72. <br /> Fire alarm systems shall be installed under permit ofthe City of Everett Building <br /> Department. Electrical inspeciions and appraval arerequired prior to calling for acceptance <br /> tests. Call (425)257-881 Q for pemiit information. <br /> 32. Fire Suonression (Sprinkler) Svstem -Ar. approved automatic suppression system shall b� <br /> provided as required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett <br /> Municipal Code. <br /> Plans for any sucl� system shall be submitted to the Building Department and the Everetl Fire <br /> Department for exaniination and approval. Such plans shall include plans for the <br /> underground mains that will supply the sprin]:ler system. <br /> Aboveground sprinkter piping shal] be hydrostaticaliy tested as estabiished in NFPA <br /> Standard 13. Underground piping shall be hydrostatically tested and flushed as established in <br /> NFPA Standard 24 for private fire mains. A.11 such tests shall be witnessed by a Pire <br /> DepaRment inspector. Call (425)157-8123 to make an appointment for inspection. <br /> Contractors'materials and test certificates shall be submitted to the�ve:ett Fire Department <br /> prior to issuance of any Certificates of Occupancy. <br /> Call (425) 257-8123 for more information. <br /> 3"s. Fire Safetv-Fire safety practices during construction shall be in compliance with Article 87 <br /> of the Uniform Fire Code. <br /> 34. Trash Collection -Dumpstcrs over ].5 cubic yards capacity shall Ue ]ocated a minimum of 5 <br /> feet from the building �LJFC 1103.2.2, 1994 Edition]. <br /> scpn00-03(,/(ahrem <br /> 7 <br />, g� ��,qp �, ^��y . � ,�:.� <br />'" .� ��',•�'r. ��:��: �;�. �����. ^�., . ^__ �` ��. "`���,.r��"�`���-3"'�<�.eH';r'4� �� ypx .J�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.