Laserfiche WebLink
> <br /> ;:�. <br /> :�-�: <br /> InspectionTvpe Date Result Remarks <br /> 9519 HOLLY DR <br /> Permit: C0711-014 Status: EXTENDED Issued: 9/19I08 Finaled: To Records: <br /> Description: NEW HOUSE- BASIC 313 <br /> Notes/Conditions: <br /> Rough in mechanical ok as noted: <br /> 1. Make sure insulation at B-vent under stairs is properly blocked- 1" minimum from combustibtes <br /> GasPiping 7!6/10 Approval <br /> ;�w InsulBldg 7/8/10 Approval As per notes �^y <br /> �. Insulation approved as noted: �<� <br /> ' ��`x 1. Need to complete insulation at wall behind fireplace <br />��` ' MechRoughln 6/30/10 Corr Reqd See nutes <br /> �t�' Corrections: <br />�';�. 1. R-8 Insulalion required on duct in garage <br />�>... 2. Insulation shield required at 8-vent in attic <br />�'`°`p 3. Proper sized PVC conduit over gas piping <br /> "—'`` 4. Properly install all spacerer at B-vent <br /> F,=�= <br /> 5. Fix screw hole on B-vent- broken strap <br />�'~ � GasPiping 6/30/10 Corr Reqd See Mech Rough notes on 6/30/10 <br /> :?;'A <br /> " StructSlab 7/1/10 Approval See notes <br /> ? Inspected slructural slab for rebar and thermal#4 bar-#2 8 thermal around heated area- R-10--Ok to <br /> � cover <br /> MechRoughln 6/21/10 Approval See notes <br /> t�' Mechanical rough in OK as noted: Wrap duct in garage to equal R-8 rating or encase in soffit. <br /> GasPiping 6/21/10 Co�r Reqd Not ready, see rotes <br /> Gas rough in not ready: <br /> ., ' , 1) Provide sleeve or grommet where gas pipe penetrates fireplace. <br />;? 2) Gas pipe not on test. <br /> Sh�arNailing 6/71/10 Approval <br /> � <br /> fi, <br /> ; PlbgRoughln 6/3/10 Approval As per notes <br /> Rough in plumbing ok as noted: <br /> � ;l 1. Water pressure over 80 Ibs requires PRV (pressure reducing valve) <br />��"'"`� PibgGrWork 4/23/10 A�proval <br /> 4 . . <br />�.. y, Siruc�Slab 4/7/10 Corr Reqd Consult-see notes <br />� Please provide GeoTech Report for the structural fill lhat has been placed to support the"Ground <br /> ;._.. <br />�,k � Slabs" per section R-403 IRC <br />; : Pooting 4/6/10 Provide geotech report, see notes ,�� <br /> Provide a geo-tech report for import materials/compaction of soils supporting footings and slab. � - <br /> I'oundation 3/23/10 Corr Reqd See notes I✓� <br /> X j Fill material needs to comply with Section R5062.1 <br />� ; Foundalion 3/17/10 Approval As per notes <br />� Inspected Foundation Walls-approved as per plans and as noted: <br />� ., 1. Contractor will complete stem walls by garage as per plans <br />�• � 2. Align rebar to center of forms <br />'`� ' !JFER Ground ?_/26/10 Approval Contrector installed UFER Ground <br />�"�; �; <br /> , ..,rJn�� ?�"i,'10 l;nnrn;-;il A= ner notes <br />� N.� . . ".� . � , „ . . �. _ .- �. �. . .. . .. � � . <br />�."��� t�•; <br /> 3�;:� <br /> '^� �rr <br />�+� f :; ._ _ . . �c . .., a^s...F. u+S.:t <br /> dyM.! ?� �n,+r.,t✓e•.tr.qiy;,:,p. A�n� � ..: 5?' q..� n �, �t " y{�� � )4 +�. . '�Y.ui'ts';;,�.th, �:n ur.! :� .� �.; x`:. .. ��� <br />�'��`^ M n '�'MF.y�, �� �f9L�F-!. �,�{�?�.� :ln `R�?�'r. 'h`'°�..• �'aw 'w.. � _^t���yi� . � <br /> _ ' - "f��-',. �"° {,,,, � c„.,.. <br /> :. '��' {�� .i e r.'. `v 's : 1"3 ""'^"^•oq"' a'�' <br /> �� j 'S' ,�a�� - d� � i� � .. \ <br /> . ' � � ;�3 u� . S�y�'d� ��,� - �7y� l <br /> a1d y .f ��,K � .Jq. - :.�{�.� <br /> � v� 3sk +; c��� � �'� � 'R F i . <br /> ::— '5. � . �>'. 1�4 1. .. . �., . � . :�.,l�x.�4�l:rt� f i...r�! ,� . <br />