Laserfiche WebLink
e <br /> .. . , . . . �..d �.� . . <br /> .�'yi,:. . . .. . .. � . . . . . <br /> ,..i�r..�.�; " . ,. .. . . . .. . ' } . <br /> . �.: <br /> �+ ir^+�arre.Mu.,.,....-.._.__. ,: . � . � . .:.:. <br /> 3 . Any grading/fill on this site shall be done so as to not impact <br /> the surrounding properties. (SEPA Earth, Land and Shoreline Use <br /> Policies) <br /> HZTIGATION REQIIIRED BY BXISTING CODES AND ORDIN?�1iCES <br /> la. A fire hydrant is required within 200 driving feet, but not closer <br /> than 50 feet, of every structure per Ordinance 473-s�. The <br /> hydrant must be located in a location approved by the City Fire <br /> Marshal, preferably on Holly Drive at the north side of the <br /> proposed driveway. <br /> lb. Based on the proposed 12,000 square feet o� Type V-1 hour, <br /> sprinklered construction, the fire flow of 1,500 GPM is required. <br /> lc. Portable Fire Protection is required, A portable fire extinguisher <br /> with a minimum UL Rating of 2A must be provided within 75 feet <br /> travel distance of all portions of each building during <br /> construction and prior to occupancy. <br /> ld. Everett City Ordinance �1759-90 requires that all apartment <br /> buildings containing more than 4 units or 3 stories or more be <br /> provided with an approved sprinkler system. The sprinkler system I <br /> must comply with UBC Standard 38-1 and/or NFPA Standard 13. Plans <br /> for any such system must be �ubmitted to the City Building and <br /> Fire Departmen�s for review and approval. Such plans must include <br /> plans for the underground mains that will supply the sprinkler <br /> system. Above ground sprinkler piping must be hydrostatically <br /> tested and flushed per NFPA Standard 24 for private mains. A11 <br /> such tests must be witnessed by a Fire Department Znspector. Call <br /> 259-8;10 to make an Inspection appointment. Contractors� materials <br /> and test certificate must be submitted to the City Fire Department <br /> prior to issuance of any Cert'.ficate of Occupancy. Call 259-8726 <br /> for more information. <br /> le. An automatic fire alarm system complying with Uniform Fire Code I <br /> standard 14-1 must be provided in each multiple family building of <br /> three (3) or more stories or containing sixteen (16) or more <br /> dwelling units. Plans must be submitted to the Fire Department for <br /> approval. Submittal shall include cut sheet of all equipment foi• <br /> use. App:•opriate trip tests must be performed and witnessed by a <br /> Fire �epartment Inspector prior to acceptance. Call 259-8710 for <br /> Acceptance Test. Fire ularm systema must be installed under permit <br /> of the City�s L�uilding Department. Inspections and approval a�•e <br /> required pr?or to Acceptance Test. Call 259-8810 for pe:mit I <br /> information. <br /> lf. In accordance with Article 10.208(a) of the Uniform rire Code, <br /> approved numbers or addresses shall be placed on all new and <br /> existing premises, buildings and apartments, in such a position as <br /> to be plainly visible and legible from the st-reet/road fronting <br /> the �roperty and access road;> within the apartment complex. The <br /> 2 I <br /> _ . _,.,.�-�...�..w _.- ,__,_ _ _. --- __._ — <br /> �. �,. . . �' . . . .. .. ... :. . .. . <br /> J+' <br />