Laserfiche WebLink
� . � :� i l�i' I.��,�1.1�_i��.�l' ' - . <br /> . .. �i�_.i �.i.�, . ....._ . . ��l . .. . 1 i 1'.. . ..�_ .i �i_.�.'._ . r <br /> BUILDING DIVISIOH � � <br /> � � PLAN CORRECTICN SIIBET Plan Check No. �5-295 <br /> . , <br /> Owner Bert Cronin Jr. Use rlultiple Pamiiy Dcaellinq <br /> Contractor Cronin Yomes Inc. Use Zoning �-3 <br /> Architect James T1. Beed Fire Zening 3 <br /> Jab Site Address Occups�ncy Group "- <br /> T,ype af Construction Occupant Load lst I'loor 13 <br /> In response to your. application for a permit, your plans and specifications <br /> have Deen examined and you are advised that the issuance of' a permit is <br /> withheld for the reasons hereinafter set forih. DIOTE CAREI'ULLY: Answer <br /> questions and make explanations IIY COP.RECTING ORIGINAL PLANS, and new plans <br /> subr�itted to the Deoartment of Building and Inspection. (T2IIS SH�ET D1UST <br /> EE RETURNED I+�ITH ORIGINAL PLANS AND SP�CIFICATIONS OR THEY h'ILL BE FILED <br /> AS NEI4 BUSINESS. ) <br /> No. L�niform Building Code 197? Edition INSP . COD� APPROVED <br /> SECT. INLTIALS <br /> 1. Plea.^,e Purnis'7 a complete plot nlan. <br /> � Z� Please furnish connlete roof specifica- j- ;.. <br /> cions in comoliance with (Section 3203 (fl_ -' �_709 , <br /> - �---r— — <br /> 3. Show on olan location an3 type of <br /> � weather resistive barrier for exterior <br /> caalls. 1707 <br /> -79 . ?lease specify on tlte nlan the type of <br /> ; wainscoating in shewer areas and that it <br /> �vill be anplied over r�aterials, other , - <br /> L-han structural elements, �ahich are noi- �l <br /> adversely affected by moisture. 1711 (d) -/" <br /> ;. Posts supnorting the building siia2l Le <br /> " ' o; on� hour fire resistive construction. 1502 .,, . ,', <br /> G. All e::terior walls in the nar;:inq f�oor <br /> shall be o` one-hour �ire-resistive <br /> construction. 1502 <br /> 7. The nark:ng floor ceiling-floor assembl <br /> shall be a one hour fire resistive . <br /> assembly as s�� forth in table 4"1-c o�' <br /> as seC forth i^ the ICnp research <br /> recommendation nFC 1692 , clear c'.etail <br /> assembly on the drawing 1�02 <br /> 8 . Show on plans that units are senera�e3 <br /> from each other by one hour fire <br /> resistive construction. i30? (b) <br /> 9. Pr.ovide t�vo esits fro� t�e `loor aUove <br /> tha first story in comnliance with <br /> s�ction 3302. 3302 (a) <br /> j ] 0 . nrovide an aporoved barrier at the base <br /> , ment portion of the stairccay where <br /> continuous to the upper floors. Sho�:� <br /> l.ocation and tgpe on n1an. 3305 (g) <br /> �!: �.1. nrovide a one hour labled self-closinq <br /> door asser�bly beL-tioeon �aser.tent an�'. <br /> upper floors. 503 (c) ; <br /> �on-ecti.ons as above indicate � <br /> wi.].]. be com��li.ed ��i.th Date <br /> O�; u" or Author�zed Agent <br /> l>agc -- 1 of 3 — <br /> ,--� <br />