<br /> 3COMPLIANCE � NWEC LOl ,�,41SE RESIDENTIAL COh. �,LIANCE CHECKLIST �.-
<br /> j RE�UIflED � -.... . .., ..,,,,,,,,.. .
<br /> � ..,, _ ._ ..... .. ........ ... , ..,._.. .. ,. .:._.... , ,.,......,, ..
<br /> � � Electricaliy heated dwellings, 5 3 stor(es, Zone 1, Western Washington
<br /> . � ... .�.
<br /> ....: ,... . . ,.. . :,,..:� ,.,,.�,.
<br /> INSPECTION ... .. ..,.,..,,.. ....,:,..:, . �:�.:.:..�.��
<br /> APPROVED �MPCRTANT: �Pleass supply Information r�quested In tho approprlate
<br /> shaded boxes below. Disregard boxes that don't descrlbe your buliding or
<br /> equi;�ment. Do NOT place checks In the }wo lett columns.
<br /> FlNAL PNASE
<br /> O O Crawl sEiace Floors wiil be insulated without compression, and with adeyuate support to:
<br /> 0 R30(Ch #6 Option I) ❑ R19 (Ch H6 Options II, III, IV) O R_(Ch#4, 5, or 7)
<br /> Non-vaulted, attic cellings wiil be insuiated without compression to:
<br /> O R-38 (Ch#6, all options) �'
<br /> O p_ ,i�taN, ��L�Ch#4,5, or7)
<br /> ar Below grade wails are insulated without compression to R19 instead of exterior'A10.
<br /> LtY p' boor systems meet: OU.19(Ch#6, (option:; I, II, III) ❑U.22(ChRs, (option I�/ ❑�i.�Ch#4 or 5)
<br /> 0 O Loosefill Insulatlon OK ih "
<br /> 1) maximum ceiling slope not > 2 1/2 in 12
<br /> 2) z30"of clear distance from top of bottom chord to ihe underside of rooi sheathing at ihe root ridge.
<br /> 6 mll polyethylene cr other approved ground cover lapped 12" at ail joints and to foundation wall
<br /> O � Clearances meei listed minimums between insulation and:
<br /> 1) chimney 2) Iight tixtures 3) IC rated recessed lights (O" clearance OK)
<br /> Attic hatch is insulated to required ceiling R-value and is weatherstripped.
<br /> 0 ❑ AII exterlor and/or garage to home doorsareweatherstripped.
<br /> � � Reclrculating servlce hot water piping is insulated as checked below(see Uniform Building Code,
<br /> Sections 1712 &1713, flame spread and smoke density requirements )
<br /> 1) i-1/2" ir.sul2tion tor main lines in attic and crawlspace.
<br /> 2) 1" insulation for branch lines in attic and crawl spac2.
<br /> � � Minlmum of one thermostat per HVAC system with proper F range of 55-75' (hea;ing).
<br /> � � Readily accesslble means to restrlct or shut-off heating Input to each zone or floor not
<br /> controlled by a thermostat.
<br /> 0 � Thermostat setback is in place and readily accessible..
<br /> � � Backup heating system controls must prohibit operation when primary heating system is
<br /> operating.
<br /> O Mechanical ventilation system must have a means tor volume reduction and shut-off.
<br /> � Supply ducts must have volume dampers tu balance system.
<br /> ❑ ❑ Supply and return aly ductwork is required to have sealed duct joints in unconditioned spaces
<br /> nd: �t11 insulation (Ch #5 and 6, all oplions) OR ❑ R_(Ch #4 Approach)
<br /> a Electric water heater(s) has :
<br /> 1) separate power shut-oft 3) ASHRAE 90A-80 Iabel on tank
<br /> 2) noncompressible R10 pad (unheated spaces only)
<br /> Shower(s) has a means to Iimit flow to 2.75 gpm or less
<br /> Flreplaces � will ❑ wlll npt be Installed: M(r. Model
<br /> Woodstoves O will ❑ wlll not be Installed: Mtr. Model
<br /> ❑ ❑ All fireplace/stove(s) have: 1)6 square inch combustion air suppty directly conected to the fire box 'li
<br /> 2)Combustion air duct with readily accessible, tight fitting damper. 3) Tight fitting glass or metai doors
<br /> p ❑ Masonry tlreplace(s)has a tight fitting flue
<br /> damper with readily accessible, manual control(s).
<br /> NWEC Final ph�ase requiremenfs:
<br /> Approved �by:
<br /> oate `71(� �
<br /> WEESAPpILVO Page 7 of 7