My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2120 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
2120
>
2120 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2022 10:09:20 AM
Creation date
2/18/2017 4:42:42 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2120
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TO Frank H. Bennett <br />kti <br />FROM Jamie G. Johnson U <br />DATE February 10, 1975 <br />SUBJECT posted Single Family Dwelling <br />2120 Hoyt <br />CITY OF EVERETT. EVERETT. WASHINGTON <br />An inspection of the referenced building was conducted by this <br />division on February 7 and the following deficiencies were found. <br />1. The complete wiring system was found to be inadcgate and <br />must be replaced. <br />2. A new electrical service must be provided. <br />3. The house shows considerable settlement about the perimeter. <br />A new solid concrete or masonry foundation must be <br />constructed. <br />4. These are signs of deterioration of the sole and sill plates <br />and the bottom ends of the studs in the exterior walls. <br />All siding within the lower 2 to 3 feet of the walls should <br />be removed for adequate inspection of these members. <br />5. The roof on the rear part of the building leaks. k.ist be <br />replaced. <br />6. Front and rear porches are unsafe and must be replaced. <br />7. The water heater must be replaced and a complying pressure <br />zQ4j c' relief valve provided. <br />R. The water heater shall be revented with approved gas vent <br />duct. <br />9. All floors shall be leveled. <br />10. All bedroom windows shall comply with Sections 1404 and <br />1405 of the Building Code. <br />11. Several windows show signs of rot about the frames. These <br />windows must be repaired or replaced. <br />12. There is not 6 feet 6 inches of head room at the top of <br />the stairs. The roof section in this area shall be <br />reconstructed to achieve clearance. <br />13. New roof flashing required at vent pipes. <br />14. warm air furnace shall be vented with approved gas type <br />vent. <br />15. The house needs to be cleaned and repainted inside and out. <br />The house appears to be of solid construction and with the correction <br />of the above items this house could be brought back to an adequate <br />standard. <br />i <br />
The URL can be used to link to this page
Your browser does not support the video tag.