My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2301 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
2301
>
2301 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2021 4:14:06 PM
Creation date
2/18/2017 4:49:31 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2301
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
260
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iL CONSTRUCTION DOCUMENTS <br />Three (3) complete sets with site plans. Minimum scale: 1/8" = 1'-0" <br />✓ <br />A. Architects stamp. All projects over 4,000 squaze feet or mo:e than 4 dwelling <br />units require the plans to be prepazed by an uchitect cunently licensed to <br />practice in the state of Washington (RCW 18.08) - Please note that an engineers <br />stamp dces not eliminate this requirement. <br />B. Foundation plans and details <br />C. Floor plan with complete dimensions (indicate entire building shawing all exit <br />doors, stairs, corridors, etc.) <br />D. Building section with vertical dimensions and building construction <br />E. Wall sections indicating proposed construction and assembly rating as required <br />for 9ccupancy separation, azea sepazation or building construction <br />F. Exterior elevations indicating proposed materials, finish grade and building <br />height <br />G. Stair or ramp pl�ns (l/�i" = I' 0" minimuni scale) and sections <br />H. Toilet room plans (1/4" = 1' U" minimum scale) and interior e(evations, indicate <br />wall and floor finishes, fixture dimensioas, handicap accessorizs (if required) <br />and toilet accessories <br />I. Door schedule (indicate frame and door rating, type of luck or latch and signage <br />if required) <br />J. Room f: :ish scheciule <br />K. Lighting plan and energy budget calculations (indicate wattage of all fixtures, <br />include exterior building mounted lighting). These must be provideci at the time <br />of building permit application. <br />L. Energy calculations <br />M. Structural drawings and calculations <br />N. Mechanical plans showing H.V.A.C. system and plumbing <br />O. Elec.rical plans <br />P. Specifications <br />Q. Copies of any permits/approvals issued by the Planning Department <br />m��emat �.��.ry �t, �9ss <br />
The URL can be used to link to this page
Your browser does not support the video tag.