Laserfiche WebLink
March 28, 2013 <br />• Dry 120c <br />18.1/4" <br />20-1/16' <br />A 11B•1/4' <br />(464) <br />(464 <br />(5101 <br />B <br />T <br />T <br />7-°I76- <br />(178) <br />(178) <br />(186) <br />� <br />16-3/4" <br />12.12" <br />14" <br />(425) <br />(3t8) <br />(356) <br />D <br />10- <br />10" <br />254 <br />254 <br />E <br />11-13/1fi" <br />.3l4- <br />(300) <br />J781 <br />F <br />23- <br />q/2 <br />23' <br />584 <br />584) <br />G <br />34.12` <br />36 <br />914 <br />E <br />The Viking Corporation. 210 N Industrial Park Drive, Hastings MI 49058 <br />Telephone: 269.945.9501 Technical Services: 877-384.5464 Fax: 269-818.1680 Email: techsvcs@vikingcorp.com <br />3" 4" 6.. <br />R <br />a A 4..86" A°1 A <br />k5( \ <br />YC <br />(— D <br />Gaareo Outlet Vake Flanged Outlet Vc" <br />W4hout Accelerator Top V.e+ W.Ih -1 Accelerctar <br />Figure 1 - Take Out Dimensions <br />Latch <br />i I 42-BDri <br />Clapper Arm HookDry Valve Fig. 2-A j Dry Volvo Fig. Valve Fig. 2-C <br />Figure 2 <br />4. INSTALLATION <br />t. For proper operation and approval, the valve must be trimmed in accortlane•,u with Viking Model f•1 Dry Valve Tim Charts <br />2 The Model F-1 Dry Valve must be installed In the vertical position as shown in Figure t <br />3 Air or nitrogen supply to the dry pipe system must be clean, dry, and oil tree <br />4 Automatic air supplies must be regulated, restricted, and from a continuous source A Viking air maintenance device should be <br />installed on each system equipped with an a�ilnmabc air supply. Never exceed SO PSI (4.1 bar) pressure in the system piping <br />with the dry valve clapper closed <br />5 The dry valve must be installed in an area not subject to freezing temperatures or physical damage. If required, provide a valve <br />house (enclosure) with adequate heat around the dry valve and Trim Freezing temperatures sndlor excessive pressure wili dam- <br />age the dry valve member assembly <br />6 When corrosive atmospheres and/or contaminated water supplies are present, it is the owner's responsibility to verify compat- <br />ibility with the Model F-1 Dry Valve and associated equipment <br />7 Consider Irstallatlon of the Viking accelerator and anti -flood device. An accelerator (quick opening device) Is recommended <br />on all differential dry pipe calves and is required on dry pipe systems of certain capacities Refer to Installation Standarrs and <br />Authorities Having Jurisdiction. If an accelerator Is to be installed, verify that the appropriate Trim Chart is used. <br />8 Prior to installing the valve, thoroughly flush the water supply piping to verify that no foreign matter Is present <br />A. C;uneral Installation Instructions <br />1 Verify that necessary Trim Charts and Technical Data for the dry valve and associated egwpmJnt are available <br />2. Remove all plastic thread protectors from the openings of the dry valve <br />3 Apply a small amount of pipe -joint con pound or tape to the external threads of all pipe connections re4-fired. Take care not <br />to allow any compound, tape, or other foreign mallet inside any of the nipples or openings of the dry v_`ve or loin compo- <br />nents <br />a Install the Model F-t Dry Valve and loin piping according to the current Model F•1 Dry Valve Trim Chart provided with the <br />Trim Package and the Viking Engineering and Design Data book The Model F-1 Dry Valve must be installed in the vertical <br />pOSdiOn. <br />5. When installing a Viking accelerator and ant ' ood device in conjunction with the Model F-1 Dry Valve, refer to the appropri- <br />P�31 <br />