My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2702 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
2702
>
2702 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2022 11:25:53 AM
Creation date
2/18/2017 5:06:13 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2702
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
510
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />Q`'P -POTTER PS40 SERIES <br />,, 5 The Symbol of Protection SUPERVISORY PRESSURE SWITCH <br />( , POTTER <br />O <br />vino ,-_, annrnmsonr <br />Ordering Information <br />Model <br />Description <br />Stock No. <br />PS40.1 <br />F.essure switch with one set SPDT contacts <br />1340403 <br />PS40.2 <br />Pressure switch with two sets SPDT contacts <br />1340404 <br />Hex Ivey <br />5250062 <br />Cover Tamper Switch Kit <br />0090200 <br />BVL <br />Bleeder valve <br />1000018 <br />;n:rallatam <br />The Ponce PS40 Series Supervisory PressureAcmated Switches are designed <br />primarily to detect an increase and/or decrease from normal system pressure <br />in automatic fire spnnlder systems 'typical applications are Dry pipe <br />systems, pre -action air/nitrogen supervision, pressure tanks, an supplies, <br />and water supplies. The PS40 switch is factory set for 40 PSI (2,8 BAR) <br />normal system pressure. The switch marked with the word LOW is set to <br />operate at a pressure decrease of If PSI (,7 BAR) at 30 PSI (2.1 BAR) The <br />switch marked with the word HIGH is set to operate at a pressure increase <br />of IOPSI(,7BAR)at50PSI(3,5 BAR) See section heading Adjustments <br />and Testing Bother dim factory set point is required <br />I. Connect the PS40 to the system side of any shutoD'or check: valve. <br />2. Apply Teflon tape to the threaded male connection on the device. <br />(Do not use pipe dope) <br />3 Device should be mounted in the upright position <br />(Threaded connection down) <br />4. Tighten the device using a wrench on the flats on the device. <br />Wiring Instructions <br />I Remove the tamper resistant screw with the special key provided. <br />2. Carefully place a screwdriver on the edge of the knockout and sharply <br />apply a force sufficient to dislodge the knockout plug See Fig. 9 <br />3 Run wires through an approved conduit comment and affix the <br />connector to the device. A NEMA-4 rated conduit fining its <br />required for out ioor use <br />UL, cUL, and CSFAI Listed, FM and LPC Appeased, 0 NILA <br />Accepted. CE Marked <br />Dimensions: 3 78' (9,6em)W x 3.20" (8,Icm)D x 4.22" (10,7cm)H <br />Conduit Entrance: Two knockouts provided for 12" conduit. individual <br />switch compartments and ground screw suitable for <br />dissimilar voltages <br />Enclosure: Cover- Die-cast with textured red powdercoat finish, single <br />cover screw and rain lip. <br />Base. Die-cast <br />Pressure Connection: Nylon 12" NPTmale <br />Factory Adjustment: PS40-1 operates on decrease at 30 PSI(2,1 BAR) <br />PS40.2 operates in Increase at 50 PSI (3,5 BAR) <br />and on decrease at 30 PSI (2,1 BAR) <br />Pressure Range: 10.60 PSI (,7.4.1 BAR) <br />Differential: Typical I lb at 10 PSI (,07 at,7 BAR) <br />4 lbs at 60 PSI (,28 at 4,1 BAR) <br />\iasimum Sys(em Pressure: 300 PSI 120.68 BAR) <br />Switch Contacts: SPDT (Furm C) <br />10.1 Amps at 1251250VAC, 2.0 Amps at 30VDC <br />Die SPDT in PS40.1, Two SPOT in PS40.2 <br />Environmental Specifications: <br />NEMA 4/IP66 Rated Enclosure - indoor or outdoor when used <br />with NEMA 4 conduit finings. <br />Temperature range. 40°F to 140OF (40°C to 60°C) <br />Tamper: Cover incorporates tamper resistant fastener that requires a <br />special key for removal. One key is supplied with each device. <br />For optional cover tamper switch ku, order Stock No. 009D200. <br />Seebulletin 05401200 PSCTSK. <br />Service Use: <br />Automatic Sprinkler NFPA-13 <br />One or two family dwelling NFPA-13D <br />Residential Occupancy up to four stories NFPA-13R <br />National Fire Alarm Code NFPA-72 <br />4. Connect the wires to the appropriate terminal connections for the <br />service intended. See Figures 2,4,5.6, and 8 <br />Adjustment And Testing <br />The operation of the pressure supervisory switch should be tested upon <br />completion of installation and periodically thereafter in accordance with <br />the applicable NFPA codes and standards and/or the authority having <br />jurisdiction (manufacturer recommends quarterly or more frequently). <br />Note Testing the PS40 may activate other system connected devices <br />The use of a Porter BVL (see product bulletin 8900067 for details) is <br />recommended to facilitate Bening and testing of the P540 pressure switch. <br />When a BVL (bleeder valve) is used, the pressure to the switch can be <br />isolated and bled from the exhaust port on the BVL without effecting the <br />supervisory press= of the entire system. See Fig. 3 <br />The operation point of the PS40 Pressure Switch wit be adjusted to any <br />point between 10 and 60 PSI R7 - 4.11 BAR) by turning the adjustment <br />knob(s) clockwise to raise the actuation point and counter clockwise to <br />lower the actuation point In the case of the PS40.2, both $%ouches operate <br />independent of each other. Each switch may be independently adjusted to <br />actuate at any point acrosss the switch adjustment range Initial adjustment <br />can be made with a visual reference from the top of the adjustment knob <br />across to the printed scale on the switch bracket. Final adjustments should <br />be verified with a pressure gauge. <br />Potter Electric Signal Company, LI-C St. Louis, MO • Phone866.956-0988/Canada 888.882-1833 • wwsvw pouersignal.com <br />PRINTED IN USA MFG=:a00930-REV E PAGE I OF 3 <br />09/I7 <br />�,,L 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.