My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3312 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
3312
>
3312 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2022 2:16:07 PM
Creation date
2/18/2017 5:47:51 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3312
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L[r. Rommel (C0306-008) <br />June 26, 2003 <br />Page 2 <br />9. Specify min�rrium finished width in bedrooms. If dimensions on plans submitted aze to the <br />face of die framing, then three of the five bedrooms would not comply wi�h the minimum size <br />for habitable rooms. (Minimum 70 sq. ft. with no dimension less than 7') <br />10. Provide smoke detectors in all sleeping rooms and in the corridor or area giving access to each <br />separate sleeping area. Betectors shall be installed on each floor and in basements. Smoke <br />detectors in new bedrooms in basement shall be hard-wired with battery back-up. <br />11. Show how the existing 3rd bedroom complies with the following requi:ements of UBC: <br />a. At least une operable window or door is required from each sleeping room. The <br />minimum net clear open able area is 5.7 sq. ft. The minimum ne� :lear open able <br />height is 24". The minimum net clear open able width is 20". 7`; minimum sill <br />height is 44" above the finished floor. <br />b. Smoke detecturs per 310.9 UBC <br />c. Ceiling lieight per 310.6.1 UBC <br />d. Minimum width per 310.6.3 UBC <br />e. Light and ventilation per Section 1203.2 and l2033 UBC <br />f. Ploor area per 310.6.2 UBC <br />12. Provide minimum 50 cfin exhaust fan in bat�iroom vented to the exterior. <br />13. Provide cross section through mechanical room. Show compliance with Section 310 UBC. <br />14. All exterior entrance/exits are required to have a landing at not more than 8" below the <br />finished floor. A door shall not open onto an exterior stair. <br />15. All wood in contact with concrete shall be pressure treated. <br />Please prepare a response lettcr showing where each item in this conection letter is addressed on the <br />plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan revie�v will <br />recommence. <br />Ali req�ired subrnittals shall be of sufficient detail and contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />��� <br />Jeff Heilman <br />Development Technician <br />oe�imu:[nntsTnnf[iuun'rt:o�oe �na iv r tiorr nvei <br />
The URL can be used to link to this page
Your browser does not support the video tag.