My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3414 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
3414
>
3414 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2022 8:05:02 AM
Creation date
2/18/2017 5:54:54 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3414
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 20, 1974 <br />CITY OF <br />everett <br />CITY HALL . 259.8865 <br />EVENETT. WASHINGTON <br />v e2oi <br />Anderson Electric INSPECTION DEPARTMENT <br />17217 Aurora North <br />Seattle, Washington 98133 <br />Reference: 3414 Hoyt I, -- <br />Everett, Washington <br />FHA 561-129598-203 <br />Dear Sir: <br />The following corrections must be made as a condition for <br />issuing the building permit: <br />1. Concrete retaining wall needed in east end of <br />basement to replace wood. <br />2. Floor joists look over-spaned. <br />3. Bedroom #1 & 2 windows do not comply with UBC <br />Sec. 1404. <br />4. 3/4" water service needed. <br />5. Lead waste on lav to be replaced. <br />6. No vent on laundry tray and no trap on automatic <br />washer. <br />7. Install back water valve on basement fixtures. <br />8. Water piping undersized. <br />9. Rear building sewer to be capped. <br />10. Portion of kitchen sink waste undersized. <br />11. Bad joints in basement on 2" cast iron to be <br />repaired. <br />Yours truly <br />Bruce A. Buck <br />Inspection Department <br />BAB:eb <br />
The URL can be used to link to this page
Your browser does not support the video tag.