My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3432 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
3432
>
3432 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2022 3:13:00 PM
Creation date
2/18/2017 5:57:46 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3432
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`"OA1 John Farrens G � <br />DATE August 16, 1971 <br />k ` <br />SUBJECT 3432 Hoyt - Roy Kelly - CITY OF EVERETT, EVERETT. WASHINGTON <br />A complaint was received 7/21/71 from Mr. Roy Kelly of 34,2 HL,�t Avenue stating <br />that there are no fire escapes from the second floor. <br />John Farrens visited the site on 7/23/71 and the following conditions exist at the <br />site. <br />1. The building is a 3 story building with apartments on the 2nd and 3rd floors. <br />The 2nd floor is at grade level at the south side of the building (34th Street). <br />2. There is one central stair. 8 apartment units exit from this stair, 4 from <br />the 3rd floor and 4 from the 2nd floor. <br />3. There is a parking garage under the building with an open stair hall from <br />the parking garage into the central stair hall, <br />4. Application for a permit was submitted and approved 1/12/68 for a 9 unit <br />apartment. <br />5. A permit was issued 1/15/68 and fin41 ed 3/26/69. <br />6. The application shows a 36' by 90' building on a 60' wide lot. <br />7. Drawings with two stairs were submitted approved and are in the file in the <br />inspection office. <br />8. The building was not constructed in accordance with the drawings that are <br />on file. <br />9. The Luilding apparently is not built as shown on the plot plan on the <br />application. <br />10. Sec. 420 of the U.B.C., defines story as a space where the floor above is <br />6 or more feet above grade for 50% of th= perimeter. <br />11. Sec. 3302 of U.B.C. states that floors above the 2nd story used for othir <br />than service to the building shall have two exits, and every portion of the <br />space shall have access to both exits. <br />12. Table 5B requires 1 hour separation between the garage and the apartment <br />occupancy. This means a 1-hour fire assemble door in stairway between <br />the two. <br />�NYINUL%llo NGl uIm.INAu N1iNk..l �JI Nlmr <br />II"Y nlul nIII <br />Lln In IIIPI luN <br />i .111 qiL NLl 1. nt Nl 1. N�clMl�nf <br />In i9Y url WIII II <br />Lul'/ Ally In Ilglb <br />IK.I/;,V/nto", ow <br />TO OkiAFTEN REMOVINU <br />YLLLOW CUYY <br />tUN IILFLBIIIpC <br />\ J <br />
The URL can be used to link to this page
Your browser does not support the video tag.