� <br />Ltc J. Staniford (CO205-018) <br />June I1, 2002 <br />Paae 4 <br />LATERAL <br />31. Braced wa11 lines should be shown on the plans. The spacing of the braced wall lines <br />should not exceed 34 ['_'S] feet on center in both Ihe lo�gitudinal and transverse directions <br />in each story. <br />32. All braced wall panels must be clearly indicated on the plans. <br />33.,'All details should be provided on the plans ior the al[emate braced wall panels. <br />y 3�#. Domestic clothes dryers should be exhausted to the outside. <br />35. The plans should show that the ducts for exhausting clothes dryers are not put together with <br />sheet metal screws or other fastening means which extend in to the duct. <br />ENERGY <br />36. The designer should note on the plans that all glazing shall be certified and labeled with its <br />U-factor by an independent agency licensed by the NFRC. <br />37. Vapor retarders having a perm ratio of one or :ess should be shown installed on the warm <br />side at all walls separa[ing conditioned space from unconditioned space. Note face stapling <br />is required. <br />38. A�round cover of 6 mil bla�;: ���;ethylene or equal should be shown laid over [he ground <br />within crawl spaces and overlapped a minimum of 12" at all joints. <br />39. Where cave vents occur, baCiling of the vent openings should be shown so as to deFlect thc <br />incoming air/above the surface of the insulation. Proper protection shall be provided <br />around recessed light fixtures so that the fixture will not become overheated. Section <br />so2. i.�.a <br />�40. To limit air leakage, exterior joints around windows and door frames, openings between <br />walis and foundations, bet�veen �aalls and roof and behvicen wall panels; openings at <br />penetrations of utility services through �valls, floors, and roof; and all odier such openings <br />in the building envelope should be sea!ed, caulked, gasketed, or weather-stripped. <br />dl. Recessed lighting fixtures, if used, should be IC rated. <br />42. The plans should clearly show how whole house ventilation is to be provided. <br />43. The location and details of the required "whole house fan" should be on the plans. <br />44. The sizes of all "source specific" fans should be specified. Washington State Ventilation <br />Code. <br />ULDLFL:+CAbISIA�llF.11�l,�\tiO:Obn19Ni].IIOI'il � j <br />S <br />