My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4618 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
4618
>
4618 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2022 1:02:12 PM
Creation date
2/18/2017 7:12:39 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4618
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
April 2, 2010 <br />Arlie Cooper <br />4618 Hoyt Ave <br />Everett WA 98203 <br />Subject: Project: <br />Job Address: <br />Plan Check No: <br />Dear Mr. Cooper: <br />Cooper <br />4618 Hoyt Ave <br />B1003-027 <br />In response to your application for a construc'ion permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions or additions may be required <br />by other departments (such as Utilities, Planning or Fire). All references refer to the (2006 <br />International Building Code,) (2006 International Residential Code,) as amended by the State of <br />Washington and/or Washington State Energy Code 2006 Edition, and adopted by the City of <br />Everett, unless stated otherwise. <br />In order for the processing of your application to continue, it will be necessary to provide <br />the Building Division with two new complete sets of drawings reflecting the corrections <br />requested. <br />1. The roof plan and elevations are different; please revise. <br />2. Show how new floor joists are supported at the existing structure. <br />3. Foundation vents shall be located within 3'-0" of all corners. <br />4. Revise elevation to show changes made on floor plan. <br />5. Provide smoke alarms per R313 IRC; show requirements on plans in existing <br />structure. <br />6. Show how loads from roof diaphragm are transferred into the exterior walls. <br />7. Provide detail for scissor trusses specific to this structure. <br />8. Provide landing at exterior entrance/exit; show requirements on plan view. <br />9. Glazing adjacent to landings within. 36" horizontally of a walking surface when the <br />exposed surface of the glass is less than 60" above the plane of the adjacent walking <br />surface shall be safety glass/R308.4 IRC. <br />Please prepare a response letter showing where each item in this correction letter is <br />addressed on the plan set. <br />4ro11iu nTcilmavâ˘I N3.037 (461811o,1 Are) <br />]f - <br />
The URL can be used to link to this page
Your browser does not support the video tag.