Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connecl side sewer per Cily Standard #601. <br /> 5. Connect side sewer per City Slandard#'s 601, 602, 604. <br /> 6. Connecl all rooftop downspouts to the side sewer. <br /> 7. Connect rooftop downspouts to the drair�age system provided for this lot. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per Ciry of Everelt Slorm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25' long. See atlachment for <br /> more delails. <br /> 9. The contractor musl meel with the Public Works Inspector lo discuss potential drainage rouling prior to <br /> beginning lhe projecl. <br /> 10. Inslall erosion conlrol measures as determined by the Public Works inspector, such as silt fence, sVaw <br /> bales, swales, or erosion blankets. <br /> �11. Inslall erosion control measures per City of Everett Slandards for small parcels <br /> 12. Remove emsion control measures upon completion of lhe projecl prior to final approval of the peonit. <br /> �3� All excavated material from foundalion, sidewalk and driveways shall be hauled to an approved, <br /> permitted sile. No wasting of material is allowed on lhis building lot. <br /> �,� No dirt, mud, rocks or debris to be lracked onto roadway. <br /> 15. No buildinc� materials to be stacked on sidewalks and sidewalks to'�e kept clean and open for <br /> pedestrian lravel. <br /> 1G. Adjusl waler meler box 1"above sidewalk grade. <br /> 7 7. Remove and replace curb, gutter and sidewalk as per Ciry of Everelt Standard Plan tt's 305A & 306 on <br /> this proposal's (ronlage as direcled by lhe Public Works Inspector(i.e. all unused driveways and any <br /> broken or damaged area musl be replaced). <br /> 1 Fi. Install a Type I concrete driveway per City of Everelt Standard;�307. <br /> , 19. Pave driveway from the (ront properly line out lo lhe street paving. <br /> 20. Conlacl lhe Water District for connecting provisions for this building's water and <br /> sewer services. <br /> i <br /> 21. A catch basin as per Cily Slandard Plan #402 with a gas trap per Standard Plan it410 is required for lhe <br /> parking area. <br /> 22. If a sewer pump syslem is lo be inslalled, lhe pressure line must discharge into a private manhole, Ihen <br /> c�revity(low across Ihe public right-of-way. <br /> 23 A sprinkler system is required for this building in compliance �vith ihe requirements of NFDA Standards <br /> 13D. <br /> Gt;c��nmenu 1 ' <br /> �=' <br />