Laserfiche WebLink
122 Inl'ercity Avenuc <br /> August 16, 1973 <br /> 1. Gvidence of infestation ot insects and vermin. <br /> 2. Ceiling I�eight is Uelow minimum code requirements in living room, utility <br /> room, and second floor bedrooms. <br /> 3. Faulty weatl�er protection, living coom wall is split or craciced, (north � <br /> east corner) , exposing area to outside. <br /> 4. ioundation and floor framing undcr living room substandard and deteriorated, <br /> 5. Top landing of basement stairs rott�ad and broken. <br /> 6. Roof gutters Lrokea causing rainwater run-off from the rooE to run down tlie <br /> � exterior wall and into tl�e wall franing. <br /> 7. The kitdten wasL'e runs onto the ground outside the buil�:in�. <br /> � 8. The kitchen sink trap is leaking into a Uucicet. <br /> 9. The kitchen sink is not veneed. <br /> 10. The bathroom lavatory lias no trap or vent. <br /> 11. Tl:e bathtub has no trap or vent. <br /> 12, Tl�e tub and laval'ory wasL-e runs into ar open drain pipe ouCside. <br /> 13. The laundry tub and floor drain in ehe Uasement are not cocnected to the <br /> sewer. <br /> 14. The laundry tuU and floor drain are not vented. <br /> 15. The wate: closet is not vented. <br /> 16. There is no cleanout on tl:e vent sl-ack. <br /> 17. Thr_� is a 2" trap off the 4" stack that has been Uacking up and running uul- <br /> on the basement floor. <br /> 18. Therc is sewagc un Chc Ua;;emcuC Ploor. <br />