My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
18 E INTERCITY AVE 2016-01-01 MF Import
>
Address Records
>
E INTERCITY AVE
>
18
>
18 E INTERCITY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2017 8:16:07 AM
Creation date
2/19/2017 8:15:54 AM
Metadata
Fields
Template:
Address Document
Street Name
E INTERCITY AVE
Street Number
18
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 . ' ' 1 <br /> � � � <br /> sr,�'� For this warksheet consider the following D�escriptive requirements <br /> ��y O Slab insufation R-10 O 8elow p2de walls R-10 ezterior or R-19 interior O Standard infiltration control <br /> a y� If you choose to use an aCemate to the above prescriptive requirements,conTact your jurisdict�u�tor information on compliance for <br /> the Component Pedormance Approach,Chapter 5. I <br /> y z~ BUILOING COMPONENi COLUMN <br /> K y� I <br /> y �'� mayh�uildsted sepaately.0 A d e�i l e dl c os sS e c t o nll o f�e a c hf o f t h e x a lip,ca'i n g and floor buihd ng om�ponents�should 6e p o tlletl on <br /> x� z� the plans and the U-value and R-values of each element in the assembly shown. <br /> y ry Q PAOPOSED ll-YALUE <br /> 0 PflOPOSED GROSS AHEA: <br /> � h o Determine the total U-value of each building component <br /> �,,, � Determine the gross(rotaq area tor each building compo- <br /> nent and record in column A.The gross area ann the net dlne Pb�rypesrof matenals can be 1 undenathe A pendiz f.r <br /> j y� area are thx same tor the windows,doors,skylights and r�„ult U-values irom lhe Stale Ener�y Office.l-B00-SS.: <br /> r H y iloors. g731 The U-value is the inverse of ihe H-value. <br /> � �'H <br /> � o� <br /> r� c�� O PHOPOSED NEf AHEA: Q pEUUIP�U UA: <br /> Determine the net area for each building component and p y the required U- <br /> y �y equals the pr ss wallToreroof area minus thellopentlng�rea- aloeslio coluain D tor each hui dinp component and record <br /> windovrs,doors,skylights,etc. <br /> in column G. <br /> O BASE CASE AREA: <br /> Q PflOPOSED UA: <br /> Determine the 6ase case area and recortl in column C. Tho Multiply the net a2as in column B by the proposed U- <br /> � '-� �..' hase case area tor walls is the total wall area minus the base ���column Humn P for each building component and record <br /> ,� case window area. Record to�l base case vrall area in <br /> column C, row-walls 1.The base�ase area for wintlows, I <br /> � sliding glass doors and other doors that are substantially <br /> i �;�° glass must add up to tb%a of the conditioned tloor arca. O UA�IfFERENCE: <br /> _� The skyligh!area is not included in the hase case scenario. qdd all of the building component wlues in the reeuired UA I <br /> Conditioned Floor Area x.15=_ Record the number column G and �ecord at the bottom of the column in the <br /> irom above in column C, row-wintlows 1. The base case box tor totals. Add all oi the building component values in <br /> E "°�� areas for the ceilinps,iloors and non-glass doors is the the proposed UA column H antl record at the bottom oi�ne <br /> � same as the proposed net area tor those building compo- column in the hox for totals.Subtract the total proposed UA <br />� nents.The 6ase case areas ara the areas used when in column H from the rotal r.�quired UA in column G and <br /> �,� determining the required UA record in the Gox for totals in column I. <br /> �. � It the answer is a positive number then the proposed areas <br /> � REUl11RED-CODE-U•VAlUES: antl U-values comply with the Chapter 5 approach to the <br /> NWEC. If thc total is a negative number then the proposed <br /> i � The U-values!isted are the minimum requi2d U•values areas and U-values do not comply wi[h the Chapter 5 <br /> -- shown in Tahle 5-1 NWEC for Zone I, Low-rise R•3 antl R-1. opproach to the NWEC. <br /> See Table 5-21or the required U-values for Zone II. �f�e proposed areas and U-values do not comply: Review <br /> �.- . � the numbers in the UA colwnns G and H. You must <br /> "; p PNOPOSEO MEASUHETO BE INSTALLED: oneror mora of he 6ullding components to ake the tar <br /> The proposed measure is the fl-value of the insul;tion in the project comply? Once you have changed ei;her the U•value <br /> huilding component(walls,ceilinqs,floors)or the tested U- o�p�oposed area for the building component(s). Find the <br /> value of the building component Qr+indows,tloors,sky- new pmposed UA and sdd up the column agam. If the total <br /> liphts,etc.). ot ihe UA difierence is Dositive then the project complies <br /> with the code. It the numher is nepative try another <br /> huiltling componen!or further decrease thr,U-value until <br /> the total for the UA ditlerence is positive. <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.