� January 28, 200� <br /> Project No. T-56>9 <br /> Prior to use, 'I'erra A.>sociates, Inc. should examine and test all materials imported to the site for use as structural <br /> I 611. <br /> Structmal fill should be placed in unifortn loose layers not ezceedin� 12 inches and campacted to a minimum of <br /> I 9� percent of the soil's maximum dry density, as determined by American Society for Testing and �faterials <br /> (ASTM) Test Designation D-698 (Standard Proctor;. The moisture content of the soil at the time ot"compaction <br /> should be within hvo percent of its optimum, as determined by this ASTM standard. In non-structural areas, the <br /> i dcerec oCcompaction can be reduced to 90 perccnt. <br /> I <br /> i4.3 Gxcat•ations <br /> All excavntions at the site associaicd with conFined spaces, such as utility tren.:hes, must Ue completed in <br /> accordance with bcal, state, or federal requirements. Based on the \\�ashington State Department of Labor and <br /> I Industries current occupational safety and health regulatinns, the existiag fill soils observed underlying the site <br /> would be classified as Type C soils. <br /> � Accordingly, side slopes on excavations in Type C soils should be sloped to an inclination of 1.5:1 <br /> (Horizontal:Vertical). Altemati��cly, utility trench sidewalls can be suppoRed by a propedy desioned and <br /> � installed slioring trench Uox. If these slope inclinations cannot be achieved due to sit� constraints, temporary <br /> � shoring �vould be required. <br /> This infonnation is provided solely for the benefit of the owner and other design consulta:us, and should not Ue <br /> � construed to imply that 'Ierra Associates, Inc. assumes responsibility for I�� site safety. It is underswod that job <br /> site safety is the solc responsibility of the project contractor. <br /> I <br /> 4.J Toimdations <br /> � Sprcad Fnntings <br /> In our opinion, thc buildi��gs may be suppartcd on com�entional sprcad Cooting foundations bcaring on <br /> �i undisturbed surfaces composed oC the existing fill soils, or ne�v swcmral till placed al �ve these competent <br /> � existing site soils. All footing subgrade should be prepared as rccommended in Section 4.2 of this report and be <br /> obscrved by a quali(ied geotechnical engineer to veriCy soi: stability prior to footing construction. It should bc <br /> I noted that the soils are sensitive to moisture variation and will be easily disturbed by nonnal co�struction activity, <br /> especially when moist or wet. If disturbed, the soil �vill not be suitable for Foundation suppon. If foundations <br /> , will be constructed during wet wcathcr, [o mitigate soil disturbance, protecting the subgrade���ith,� four-inch layer <br /> � of crushed Uallast rock or lenn concrete mis should be considered. <br /> Pcrimeter foundations exposed to the weathcr sl�ould bear at a minimum deptl� of 1.5 feet below final exterior <br /> grades for Gost protection. Interior foundations cv� be constructed at any convenient depth belo�v tl�e floor slab. <br /> Ne recommend designing founda:ions For a net allowable bearing capacity of 3,000 pounds per square foot (ps�. <br /> Por short-term loads, such as wind anct seismic, a one-third increase in this allo�vable capacity can be used. Nith <br /> � the anticipated loads and Il�is b�aring svess applicd, building settlements should be less than one-half inch total <br /> and one-quaner diCCercntial. <br /> i <br /> i <br /> Pagc No. � <br /> � �a`� <br />