Laserfiche WebLink
l <br /> I ��� � <br /> �� <br /> F R A N K L I N ���; .�,:n ,���:��c Fr� .��� �z�-3��:� <br /> /► Suite 202 FA?( 425 827-6252 <br /> E���������{a Y,irkl�nd, WA 98033 hvacC��fr,,nklinen9 c�om <br /> A4FC�'r1N!CAL CONSULTIiA'v <br /> 3c�sia-o3�f <br /> October 17, 2005 <br /> ENVELOPE SUMMARY <br /> RE: Western Pacific <br /> 1101 Industry St <br /> Everett, WA <br /> Heated space applies to Office space. <br /> Vertical Glazing (Exteriorl: U=0.55, SHGC=0.45. Unlabeled glazing - 1/2" space Air, <br /> low-e1010j, fixed, �efault. Or certified tested assembly per NFRC. <br /> Vertical Glazing (Re-lites to Warehouse►: U =0.75, SHGC=exempt. Unlabeled glazing - <br /> 1/2" space Air, fixed, default. Or certified tested assembly per NFRC. <br /> Doors (Opaquel: Wood, U=0.50, default. <br /> Otlier Roof Type 1 (Officel: R-19 riyid insulation. U=0.05, calculated. <br /> Other Roof Type 2 (Break Rml: R-19 batt insulation in metal framinc�, 16" oc. U=0.11 , <br /> calculated. <br /> Wall Type 1 (Opar�ue, Exterior, Floor to 70'-0" AFFI: Concrete, min. 6" thick, furred with <br /> metal studs, 3-1/2", 24" oc with R-13 batt insulation, U =0.11 , calculated. <br /> Wall Type 2 �ONaque, Exterior, 10'-0" AFF to Structure Above►: Concrete, min. 6" thick, <br /> with R-19 6att insulation stickpinned to concrete, U=0.05 calculated. <br /> Wall Type 3 (Opaque, OfficelWarehouse►: eb��tal studs, min. 5-1/2", 24" oc with R-19 <br /> batt insulation, U =0.091 default. <br /> Wall Type 4 (0paque, Break RmlWarehouse): Metal studs, min. 3-1/2", 24" oc with R-13 <br /> batt insulation, U =0.12 default. <br /> (�� <br /> �yJ <br />